-
Fast™ Addressing Integral Short Circuit Isolator Loop Powered Adjustable from 7.5 to 3m Room Coverage Volume 2.4 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 17 & 23 -
FAST™ Addressing Integral Short Circuit Isolator Loop Powered Adjustable from 7.5 to 3m Room Coverage Volume 3 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 17 & 23 -
FAST™ Addressing Integral Short Circuit Isolator Loop Powered Adjustable from 7.5 to 3m Room Coverage Volume 3 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 17 & 23 -
LED Technology for Long Service Life Cost effective installation solution (Talking Sounder and Visual Alarm Device (VAD) in one device) Quick and Simple to Install FAST™ Addressing Loop Powered and Integral Short Circuit Isolator High Output Electronic Sounder 2.4 Metres (m) Mounting Height Approved to EN54 Part 17 & 23 -
LED Technology for Long Service Life Cost effective installation solution (Talking Sounder and Visual Alarm Device (VAD) in one device) Quick and Simple to Install FAST™ Addressing Loop Powered and Integral Short Circuit Isolator High Output Electronic Sounder 2.4 Metres (m) Mounting Height Approved to EN54 Part 17 & 23 -
Key Features:; Protec Algo-Tec™ 6000 Protocol Ideal where Smoke Detection is Unsuitable Fast Response Thermistor Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms -
LED Technology for Long Service Life Quick and Simple to Install FAST™ Addressing Loop Powered and Integral Short Circuit Isolator High Output Electronic Sounder 2.4 Metres (m) Mounting Height Adjustable 7m to 5m or 3m Room Coverage Volume Approved to EN54 Part 3, 17 & 23 -
Protec Algo-Tec 6000 Protocol Loop Powered High output electronic sounder Low current consumption Integral short circuit isolator Weather-proof to IP65 Choice of colours -
LED Technology for Long Service Life Quick and Simple to Install FAST™ Addressing Loop Powered and Integral Short Circuit Isolator High Output Electronic Sounder 2.4 Metres (m) Mounting Height Adjustable 7m to 5m or 3m Room Coverage Volume Approved to EN54 Part 3, 17 & 23 -
Protec Algo-Tec 6000 Protocol Loop powered High output electronic sounder High intensity LED beacon Low current consumption Choice of colours Weatherproof to IP65 Integral short circuit isolator -
Dual Technology Sensor Combined Smoke and Heat Sensors Ideal Multi-application Sensor Independent Channel Control Day/Night Operation Protec Algo-Tec™ 6000 Protocol Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms -
Key Features:; Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Key Features:; Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Low Power – The power consumption of the repeater has been minimised through energy efficient design, preserving loop current and capacity. Quiescent 1.6mA, Alarm 12.7mA Installation – The repeater can be surface or flush mounted as standard, allowing gland or conduit entrance through the rear, top or bottom of the enclosure. The device only requires a loop connection to provide both power and data, no network cabling, or external power supply is required. Event Display – Events are categorised and clearly displayed for intuitive navigation of the system status, whilst large graphical indicators show a general system overview. User Assistance – A help menu displays a list of status specific tool-tips to aid the user in accomplishing tasks, such as silencing the internal buzzer or performing a lamp test. If the user requires additional help, the contact details for site engineers and the installer are available on the screen. Multi-Language Support – The 6000/LOOP/REPEATER’s graphical user interface caters for most Western European languages and Arabic script as standard. The language for event strings is inherited from the control panel. USB Configuration – The fast USB configuration tool allows the device to be programmed with site specific data, such as contact details for site engineers and the installer along with custom logos and settings. -
Protec Algo-Tec 6000 Protocol Loop powered High intensity LEDs Extremely long service life Integral short circuit isolator Ultra low current consumption Weather-proof to IP65 -
Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Protec Algo-Tec™ 6000 Protocol Low Power Usage FAST™ Addressing Cost Effective -
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe -
-
-
Heavy Duty Sampling Pipe Combined Filter & Condensation Trap 25mm Sampling Pipe Inlet/Outlet Airflow Direction Indicator Reduces Service Intervals Reduces Unwanted Alarms Replaceable Filter Cartridge Available -
Heavy Duty Sampling Pipe Combined Filter & Condensation Trap 25mm Sampling Pipe Inlet/Outlet Airflow Direction Indicator Reduces Service Intervals Reduces Unwanted Alarms Replaceable Filter Cartridge Available -
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013" -
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013" -
Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013 -
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement -
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement User Walk Test -
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode (only one zone at once in user mode) Disablement of detector circuits Disablement of alarm circuits Disablement of any programmed delays Disablement of the optional fire link interface -
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode Disablement of detector circuits Disablement of alarm circuits; Fire Detection Zones Fully Compliant with EN54 Parts 2 & 4 Manual Device Activation Indication Coincidence Detection Non-latching Zones Zone Disablements Alarm Disablements User Walk Test -
-
Discrete Anti-Tamper Security Latch Latching ‘Fire’ LED Range of Base Options Maximum Sensitivity to Heat Detection High Resistance to False Alarm Approved to EN54 & AS7240 Part 5 -
Discrete Anti-Tamper Security Latch Latching ‘Fire’ LED Range of Base Options Maximum Sensitivity to Heat Detection High Resistance to False Alarm Approved to EN54 & AS7240 Part 5 -
Enhanced Sensitivity to a Wide Range of Smoke Types High Resistance to False Alarm Ultra-Low Quiescent Current Latching ‘Fire’ LED Range of Base Options Approved to EN54 Part 5 & 7