-
Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
-
ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S)
-
Continuous detection despite extremely large monitoring area Easy and rapid installation of the maintenance-free sensor cable Very high resistance to extremely contrary ambient influences(immune against heat, cold, humidity, corrosion, strong winds and draft) Undiminished precision under electromagnetic interference Unprecedented security against false alarms Very high sensor cable service life of up to 30 years Temperature profile over the complete measurement range delivers exact information of location, size and spreading of the fire Very low maintenance costs as the maintenance and the trouble shouting can be done from the control unit VdS certified to EN 54/5-A1 One controller unit will drive up two 8km spurs or one 8km loop Easy integration into existing installations Each sensor cable divided into up to 256 zones Individual configuration of 5 alarm criteria per zone Good network connection through Modbus, TCP/IP, FTP and SCPI interfaces
-
Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage
-
Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
-
Responds to stationary flames with no flicker Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised
-
Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered
-
Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage
-
Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols
-
Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols