Key Features:; It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Tones can be used for other purposes in addition to warning of fire, ideal for schools Enables soft start option, ideal for hospitals and nursing homes Electronic bell tone
-
‘Plug and Play’ terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
-
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
-
Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
-
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
-
Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
-
Key Features; Resettable operating element Easy access, front reset mechanism Ergonomic reset key Double pole change-over contacts Suitable for semi flush or surface mounting Optional transparent hinged cover
-
Full icon-based, easy-to-use LCD display on the low level controller for ease of commissioning, testing and maintenance Aesthetically pleasing to suit modern architectural buildings and heritage sites Range 5 to 120 metres Laser assisted alignment combined with easy to use alignment LED's enables installation by one operator Separate Fire/Fault Relays per Detector Selectable sensitivity/threshold levels Automatic Gain control (AGC) for drift compensation
-
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
-
Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Installation Guide