/All Products
  • 2 loops expandable to 4 with up to 256 zones Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure with username and password History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 2 loops with up to 128 with Fire Brigade & Fire Protection controls zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 2 loops expandable to 4 with up to 256 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 1 loop with up to 64 zones Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure with username and password History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 1 loop with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizards and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizard and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Remote control and indication Up to 32 remote units connected to each main panel 4 row 160 character LCD Replicates main panel fascia Restore disabled sounders facility
    Details
  • Key Features:; One or Two loop addressable fire alarm panel (64, 126 or 252 device capacity) Certified to EN54 parts 2 & 4 User definable zones Option for zonal or common alarm operation Options for I/O operation Alarm verification (help prevent false alarms) User selectable languages Set of changeover relay contacts for fault condition Set of changeover relay contacts for fire condition 2,048 event log (fire & fault) Zone or device disablement One-man test mode Plug & play, no need for any special tools or laptop for commissioning Fully integrated keypad All associated devices are loop powered
    Details
  • 1-4 loop, expandable by loop cards 20 zone LEDs 250 programmable zones Multi-language support (English, Spanish, Portuguese, French, Hungarian, Italian, Lithuanian & Dutch) Day/night mode delays 4 x 40-character LCD display Real Time Clock 4096 entry event logs 20-character device text 18-character zone text Zone or Device Disablement 2 x conventional sounder circuits Aux 24V supply 1 x fire relay 1 x fault relay Outputs programmable by zones Can be configured via PC or via Panel
    Details