/All Products
  • 5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
    Details
  • 5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
    Details
  • Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Key Features:; Compatible with the Notifier Range of Analogue Addressable Fire Alarm Control Panels. Including the Notifier ID3000, Notifier ID2000, Notifier ID50 and Notifier ID60 Panels. Part of the New Notifier Opal Range of Analogue Addressable Detectors. Colour : Ivory (To Match Colour of Previous Notifier Detectors and Bases) New Replacement for the Notifier SDX-751EM Detector Backwards Compatible with Existing Notifier Systems LPCB Approved Tri Colour LEDs
    Details
  • CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • Notifier MCP1A-R470SG-01 Conventional Surface Call Point with 470 Ohm Resistor
    Details
  • Notifier MCP1A-R470FG-01 Conventional Flush Call Point with 470 Ohm Resistor
    Details
  • Unique ‘Plug & Play’ installation concept Re-settable operating element option Analogue addressable communications Semi-Flush or surface mounting Fully compliant with EN54, Part 11 Backward compatibility Enhanced aesthetics Integral LED Integral loop isolation option
    Details
  • Key Features:; Unique ‘Plug & Play’ installation concept Integral loop isolation Analogue addressable communications Fully compliant with EN54, Part 11 Backward compatibility Integral LED
    Details
  • Key Features:; Unique ‘Plug & Play’ installation concept Integral loop isolation Model available protected to IP67 Re-settable operating element Analogue addressable communications Fully compliant with EN54, Part 11 Backward compatibility Integral LED
    Details
  • Key Features:; Proven reliability with a feature set that offers significant benefits to the customer Certified to EN54 Part 11 Single Pole Key removable in both positions
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • The ID61 is housed in a slightly larger enclosure (500mm x 400mm x 110mm) than the ID60 to accommodate for an internal mounted printer. A larger separate power supply (3A) is fitted in the ID61 to cater for the more power hungry applications.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • With A compact enclosure (380mm x 365mm x 110mm) and a single PCB with on-board power supply (1.5A), the ID60 provides the user with an easy to install/maintain Fire Alarm System.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • Key Features:; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 3 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1x 020-548 - Optional status indicator board kit for 7A PSU 1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H:620mm W:500mm D:122mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer 1 x 020-541-009 - 7A PSU/78AH battery cabinet kit
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 2 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 1 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 Loops 1 x 020-579 - 7A PSU 4.5A or 7A User selectable 1 x 020-543 - Dual transmittion path board kit 1 x 020-588 - Dual loop board kit 1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H:620mm W:500mm D:220mm. 1 x 020-480-009 - Main cover kit 1 x 020-485-009 - Extension cover blanking kit 1 x 020-481-009 - Extension cover kit
    Details
  • Certified to EN54 parts 2 and 4 Up to 198 devices per loop (99 sensor and 99 modules) Expandable from 2 to 8 loop capacity Adjustable sensor sensitivity Drift compensation Inter link options Master / Slave Configurable day / night sensitivity adjustment Addressable device LED blink control Automatic or Manual “Loop Learn” options Automatic device “high test” at configured time of day “Walk Test” function by zone for efficient commissioning Configurable “walk test” time limit Auto-program option 600 event history file Duplicate address fault monitoring 2 optional user configurable communication ports Dual pulse rate capability for outputs Pulsing loop powered sounders capability with steady override Non-alarm non-latching addressable device support for lower priority functions Variety of Mounting options Automatic time control functions by day of week for “Control-by-Event” (CBE) Time of day and day of week exclusions for “CBE” Remote reset output capability for peripheral equipment Configurable rapid response from manual call points (less than 3 seconds) 80 Zone capacity per panel Zone sub-division to cells for “CBE” Coincidence detection configurable by zone or cell for “CBE” Fire and fault verification delays configurable by address Pre-defined device type characteristics Output device test activation by address Selective event log display or print by date and time Full configuration edit capability from panel or PC Multiple options for RS232 port protocol
    Details