Key Features:; ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 °C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Flameproof Datasheet Apollo - Flameproof Installation Guide
-
ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide
-
ATEX & IECEx certified: II 1 G CENELEC/IEC Certified: Ga Ex ia IIC T4 Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP65 rated Supply voltage 14 to 30Vdc Operating temperature -10°C to +40°C (T4) Operating temperature -10°C to +55°C; Apollo - Datasheet Apollo - Installation Guide
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Datasheet (1) Apollo - Datasheet (2) Apollo - Product Guide Apollo - Installation Guide Apollo - Datasheet (3)
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - Intrinsic Safety - Datasheet Apollo - I.S. Detector - Installation Apollo - I.S. Detector - Product Guide Apollo - Datasheet Apollo - Orbis - Datasheet Apollo - Leaflet
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Datasheet Apollo - Datasheet (2) Apollo - Datasheet (3) Apollo - Leaflet
-
Environmental Characteristics; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Installation Instructions Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - I.S Detector - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S Detector - Datasheet Apollo - I.S. Detector - Installation Guide Apollo - I.S. Detector - Product Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Apollo - I.S Detector - Datasheet Apollo - I.S Detector - Datasheet (2) Apollo - Intrinsic Safety - Datasheet Apollo - Leaflet
-
Key Features:; Can be used for applications where smoke detectors are unsuitable. Ideal in environments that are dirty or smoky under normal conditions. Reduced incidences of false alarms. Increased reliability of detection.; Apollo - I.S. Detector - Product Guide Apollo - I.S. Detector - Installation Guide Apollo - Leaflet Apollo - Datasheet Apollo - Intrinsic Safety - Datasheet Apollo - Datasheet (2)
-
Installation:; Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm; Apollo I.S. Multisensor - Data Sheet Apollo I.S. Multisensor - Installation Manual Apollo I.S. Multisensor - Sales Leaflet About Orbis I.S. Orbis Product Guide
-
Operation:; Can be used for applications where smoke detectors are unsuitable Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection; Orbis ORB-HT-51146-APO - Data Sheet Orbis ORB-HT-51146-APO - Installation Guide About Orbis I.S. Orbis I.S. Product Guide Orbis I.S. Sales Leaflet