  • Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
    Details
  • Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
    Details
  • Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Series of product approvals; 601F Detector - Data Sheet
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection High sensitivity -up to 100 ft.(30m) HD video output with Automatic HD video recording of fire events Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-H2-HD - Data Sheet F-Guard IR3-H2-HD - Operators Manual
    Details
  • Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual
    Details
  • High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet
    Details
  • Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-F-HD - Data Sheet F-Guard UV-IR-F-HD - Operators Manual
    Details
  • High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-HD - Data Sheet F-Guard UV-IR-HD - Operators Manual
    Details
  • Key Features:; Class 1 performance as defined in BS EN54-10:2002 (range up to 25 m) Single IR technology Robust and slim design Low current consumption Easy to install Fits any of the CDX Range of mounting bases Twin LEDs for 360 degree viewing Approved by LPCB & VdS; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Installation Instructions Hochiki - Flame Detector - Leaflet
    Details
  • Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB and GL SIL2 Approved variant available; Hochiki - IS Technology Guide Hochiki - Rate of Rise Detector - Specification Hochiki - Smoke Detector - Installation Guide Hochiki - Heat Detector - Datasheet Hochiki - IS Technology - Application Notes
    Details