  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps; Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Multi spectrum design - for long distance detection and high false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities; Spectrex 40/40I - Data Sheet Spectrex 40/40I - User Guide Spectrex 40/40I - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40LB - Data Sheet Spectrex 40/40LB - User Guide Spectrex 40/40LB - Accessories
    Details
  • Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories
    Details
  • Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories
    Details
  • Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories
    Details
  • Key Features:; High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling; Flame Detector - User Manual Flame Detector - EXD Installation Guide Flame Detector - IS Install Guide Flame Detector - Maintenance Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?