  • High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002 IR2 Flame Detector Range; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling These sensors have been approved by Baseefa (notified body no: 1180) to EN60079-0, EN60079-11 and EN60079-26. The requirements of Directive 94/9/EC, the ATmosphere EXplosives ATEX Directive have also been met. Apparatus Certificate Number: BAS02ATEX1001 System Certificate Number: Baseefa08Y0078 Certified to: ATEX: II 1 G CENELEC/IEC: Ga Ex ia IIC T4; Zones 0, 1, 2; Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Brochure Flame Detector - Maintenance Guide Flame Detector - IS Install Guide Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Talentum - 16289 - Datasheet
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA,Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Intrinsically safe (IS) for hazardous areas. Die cast zinc alloy housing Ideal for use on machinery protection applications; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA, Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Die cast zinc alloy housing Ideal for use on machinery protection applications Continues operation at temperatures up to 55°C; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can you Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist High ambient temperature applications Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: II 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 Zones 1, 21, 2 and 22; Talentum IR3 Exd - Data Sheet Talentum Exd IR3 - Product Brochure Talentum IR3 Exd - Installation Guide Talentum IR3 Exd - User Manual Talentum IR3 Exd - Maintenance Guide Talentum IR3 Exd - One detector for every application Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Key Features:; Excellent immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10: 2002; Atria Coal Handling Pharmaceuticals Printing Spray Booths Nuclear Industry Waste Tips Storage Tanks Tunnels; Flame Detector - Maintenance Guide Flame Detector - Wiring Diagram Flame Detector - IS Install Guide Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Data Sheet Flame Detector - Brochure Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect
    Details
  • Excellent immunity to false sources Increased environmental protection Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: I I 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 [Zones 1, 21, 2 and 22] SIL 2 rated; Talentum IR3 - Data Sheet Talentum IR3 - Product Brochure Talentum IR3 - Installation Guide Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangers Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Talentum One Detector for Every Application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What types of flames can Talentum detect?
    Details
  • Key Features:; Highest immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Aircraft hangars Engine rooms Engine test facilities Generators High voltage equipment Nuclear industry Power plants Storage tanks; Flame Detector - Maintenance Guide Flame Detector - User Manual Flame Detector - Wiring Diagram Flame Detector - Installation Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Highest immunity to false sources Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel loading racks Storage tanks Aircraft hangers Petrochemical onshore/offshore Biomass storage and handling LNG/LPG production; ATEX: II 2GD Ex d IIC T6 [Zones 1, 21, 2 and 22] Worldwide approvals include EN54:10, with VdS and LPCB; Talentum UV / IR2 - User Manual Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - Maintenance Guide Talentum UV / IR - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose What types of flames can Talentum detect?
    Details
  • Highest immunity to false sources Solar blind High ambient temperature applications Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details