Key Features: Uses high intensity LED (white flash only) EN 54-23 Compliant Category W. VAD Coverage W-2.5-7 Automatic LED check when VAD activated Flash rate 0.5Hz Fault signal if LED check failed Locking mechanism (grub screw) Wide angle of visibility Synchronised with the Apollo Protocol
-
The base mounted flame detector bracket combines a bracket and Deckhead Mounting Box.
-
Key Features: PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
-
Key Features: PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest? for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
-
Key Features: Dual heat sensors PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
-
Key Features: Dual heat sensors PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
-
Key Features: Dual heat sensors Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
-
Key Features: Dual heat sensors Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
-
The Soteria Dimension Mounting Box is moulded from white flame-retardant polycarbonate. Positions for either side or top cable entry are marked on the outside of the Mounting Box to ensure correct cable positioning.
-
Key Features: Low profile design Utilises digital CoreProtocol communications Compatible with Discovery and XP95 systems Integrated switchable isolator as standard 8-way DIL switch addressing Drift compensation FasTest for quicker testing Tricoloured LED status indicator Comprehensively tested to exceed EN 54-7 and EN 54-17 standards Ruggedized metal face plate which is secured with anti-tamper screws Designed and tested to meet the requirements of Ministry of Justice specification STD/E/SPEC/038 Independently certified to DHF TS001 for anti-ligature use in specialist areas
-
Key Features: Low profile design Utilises digital CoreProtocol communications Compatible with Discovery and XP95 systems Integrated switchable isolator as standard 8-way DIL switch addressing Drift compensation FasTest for quicker testing Tricoloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 and EN 54-17 standards Locking mechanism (grub screw)
-
Key Features For use with conventional systems A choice of 32 tones including all the major international standards Simple First Fix installation Volume control - typical 8dB