Pack of 10 transparent hinged covers which have been designed to fit on all Apollo manufactured manual call points. The covers help to provide extra security and protection against accidental operation.
-
The Flame Detector Weather Shield protects the device from inclement conditions. Key Features Protects against water ingress Protects sensor from direct sunlight
-
Key Features: Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90 field of view Up to 40m coverage
-
The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It is a stainless steel mounting bracket adjustable in two axis. Not suitable for Base Mounted Flame Detectors. Key Features: Allows flame detector to be mounted in any orientation.
-
Key Features Protects against water ingress Protects sensor from direct sunlight
-
Key Features: Continually corrects itself against building movement Controlled and adjusted from ground level Use XP95 Switch Monitor to interface it to an addressable loop
-
Key Features ATEX certified IECEx certified
-
Key Features: ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
-
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
-
Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
-
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
-
Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation