  • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
    Details
  • Patented venturi pipe and duct housing One-pipe air sampling system Uniguard Superflow New cross-section (shape) of the venturi pipe gives an optimum of venturi effect Test hole on cover Simple installation Sensitive flow indicator Simple service and maintenance Installer-friendly connection of cables Foolproof installation of venturi pipe
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Photoelectric, integrated low-flow technology Air velocity rating from 1.5 m/s to 20.3 m/sec Versatile mounting options in square or rectangular configuration with modular construction Plug-in sensor Superb false alarm immunity with the latest sensor technology Broader ranges for operating temperature (-20ºC to 70ºC) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover Increased wiring space with 15mm and 20mm conduit knockout Improved LED status 24 VDC Backward compatibility with existing DH400 range, including remote accessories
    Details
  • High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
    Details
  • Modular Design – Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap. Zoned aspirating smoke detection – Individual detector modules provide detection for individual areas or zones, specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module. Simplified installation – Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit. Intuitive user interface – Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics. Easy pipe connection – The quick fit pipe adaptor system locks down securely, yet leaves plenty of room for easy pipe connection and removal. Quick location of smoke – Each detector module is self-contained, which means no delays in determining in which zone (sampling pipe) smoke is present.
    Details
  • Modular Design – Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap. Zoned aspirating smoke detection – Individual detector modules provide detection for individual areas or zones, specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module. Simplified installation – Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit. Intuitive user interface – Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics. Easy pipe connection – The quick fit pipe adaptor system locks down securely, yet leaves plenty of room for easy pipe connection and removal. Quick location of smoke – Each detector module is self-contained, which means no delays in determining in which zone (sampling pipe) smoke is present.
    Details
  • Modular Design – Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap. Zoned aspirating smoke detection – Individual detector modules provide detection for individual areas or zones, specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module. Simplified installation – Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit. Intuitive user interface – Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics. Easy pipe connection – The quick fit pipe adaptor system locks down securely, yet leaves plenty of room for easy pipe connection and removal. Quick location of smoke – Each detector module is self-contained, which means no delays in determining in which zone (sampling pipe) smoke is present.
    Details
  • Modular Design – Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap. Zoned aspirating smoke detection – Individual detector modules provide detection for individual areas or zones, specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module. Simplified installation – Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit. Intuitive user interface – Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics. Easy pipe connection – The quick fit pipe adaptor system locks down securely, yet leaves plenty of room for easy pipe connection and removal. Quick location of smoke – Each detector module is self-contained, which means no delays in determining in which zone (sampling pipe) smoke is present.
    Details
  • Data storage units Prison cells Plant rooms Air conditioning units Equipment racks Computer rooms Air duct protection Heritage property protection Critical equipment Anti-smoking enforcement Motor rooms; High sensitivity provided by laser based forward light scatter for reliable early warning Combined sampling pipe up to 200m in length (still air) Unique ClassiFire® Perceptive Artificial Intelligence system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protected environment and dust separation system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system RS485 communications built in as standard for networking and remote communications Large area aspirating smoke detector, up to 2000m2 coverage CPR, LPCB, VdS, NF, CSIRO, UL & FM approved
    Details
  • Data storage units Prison cells Plant rooms Air conditioning units Equipment racks Computer rooms Air duct protection Heritage property protection Critical equipment Anti-smoking enforcement Motor rooms; High sensitivity provided by laser based forward light scatter for reliable early warning Combined sampling pipe up to 200m in length (still air) Unique ClassiFire® Perceptive Artificial Intelligence system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protected environment and dust separation system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system RS485 communications built in as standard for networking and remote communications Large area aspirating smoke detector, up to 2000m2 coverage CPR, LPCB, VdS, NF, CSIRO, UL & FM approved
    Details
  • RS485 communications built in as standard for networking and remote communications Network control of 127 detectors Built in Short Isolators for optimum reliability; Data storage units Prison cells Plant rooms Air conditioning units Equipment racks Computer rooms Air duct protection Heritage property protection Critical equipment Anti-smoking enforcement Motor rooms
    Details
  • Data storage units Prison cells Plant rooms Air conditioning units Equipment racks Computer rooms Air duct protection Heritage property protection Critical equipment Anti-smoking enforcement Motor rooms; Ultra-small low-cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Single sampling pipe up to 50m in length (still air) Unique ClassiFire® Perceptive Artificial Intelligence system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protected environment and dust separation system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system
    Details
  • Analogue Addressable Smoke Sensors: ACA-E, ACC-E, ALG-E, ALN-E, ATJ-E (all variants) Analogue Addressable Bases: YBN-R/3, YBN-R/3(SCI) (all variants) Conventional Smoke Detectors: SLR-E3, SLR-E3N (all variants) Conventional Bases: YBN-R/6, YBN-R/6SK, YBO-R/6R, YBO-R/6RN and YBO-R/6RS (all variants) Comes with a standard 600mm sampling pipe, other pipe lengths available separately.; Allows air duct sampling using standard detector or sensor Fits either square or round section ducting (with additional bracket) One-tube air sampling system Simple installation/ maintenance with installer-friendly connection of cables Supplied with standard 600mm sampling pipe
    Details
  • Allows air duct sampling using standard detector or sensor Fits either square or round section ducting (with additional brackets) One-tube air sampling system Test hole on cover Simple installation / maintenance Sensitive flow indication Installer-friendly connection of cables
    Details
  • High sensitivity provided by laser based forward light scatter for reliable early warning Four sampling pipes up to 200 m (aggregate) in length (still air) False alarms reduced by unique dust discrimination RS485 communications for networking and remote communications Command Module allows control over other FIRElink units on network
    Details
  • Volt-free Fire-1 and Fault relay outputs are provided for remote monitoring by local fire detection or BMS systems High sensitivity provided by laser based forward light scatter for reliable early warning Four sampling pipes up to 200m (aggregate) in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications
    Details
  • Ultra-small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Two sampling pipes up to 100 m (aggregate) in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications
    Details
  • Ultra-small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Single sampling pipe up to 50 m in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications
    Details
  • IAS800 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two pipe runs. IAS801 single inlet pipe configuration which can be fitted with one detector.; Ideal for areas where access is restricted, harsh environments and areas where a point detector would be damaged Powerful Fan Up to two 100m pipe runs available Pipes can be individually monitored for air flow with LED bar graph FireClass loop and 24Vdc connections Fault monitored via the FireClass loop IP65 enclosure Field serviceable air filters Uses standard 25mm VESDA pipe and fittings
    Details
  • IAS800 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two pipe runs. IAS801 single inlet pipe configuration which can be fitted with one detector.; Ideal for areas where access is restricted, harsh environments and areas where a point detector would be damaged Powerful Fan Up to two 100m pipe runs available Pipes can be individually monitored for air flow with LED bar graph FireClass loop and 24Vdc connections Fault monitored via the FireClass loop IP65 enclosure Field serviceable air filters Uses standard 25mm VESDA pipe and fittings
    Details
  • DPK6 for use with FC460PH with built-in 4B-C 4” continuity base. Designed to comply with EN 54-27. One-pipe air sampling system. Patented Cap-up Venturi pipe and duct housing. Test hole on cover. Simple installation. Sensitive flow indicator. Simple service and maintenance. Range of aluminium probe tubes are available for ducts up to 2700 mm.
    Details