Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure -
Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure -
-
-
-
-
-
-
Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms, and self-test (active repeater only) “Access Enable” key-switch on active repeater -
Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms, and self-test (active repeater only) “Access Enable” key-switch on active repeater -
Key Features:; Morley IAS Analogue Addressable Protocol Clear Lens Red Flash EN54-23 Compliant Requires B501AP base for installs -
Key Features:; Large cable access EN54-3 approved Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder and strobe Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel) Positive “poke yoke” engagement Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls -
Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder and strobe Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel) Positive “poke yoke” engagement Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls -
Key Features:; Large cable access EN54-3 Approved Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls -
Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls -
Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls -
-
Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
-
-
-
-
-
Key Features:; Unique ‘Plug & Play’ installation concept Re-settable operating element option Analogue addressable communications Fully compliant with EN54, Part 11 Backward compatibility Enhanced aesthetics Integral LED Integral loop isolation option -
Characteristics common to the rest of the S2 range described in the MI-PSE-S2 detector. Dimensions in mm: 102 Ø x 43 (height) mounted on base B501AP Approved according to: EN54-7 CPD Certificate: 0832-CPD-0195 -
Combined transmitter and receiver unit Range 10-100 metres using the long range reflector kit 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-Red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom ±10° horizontal and vertical beam alignment Automatic drift compensation Loop powered Complies to EN54-12 Extended Warranty -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector -
Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder Low current draw enables more devices on loop Adjustable volume control (on device or from panel) Intense strobe output Deep and high IP base options Pure White or Ivory body colours Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel) -
-
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4 -
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4