  • Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Photoelectric, integrated low-flow technology Air velocity rating from 1.5 m/s to 20.3 m/sec Versatile mounting options in square or rectangular configuration with modular construction Plug-in sensor Superb false alarm immunity with the latest sensor technology Broader ranges for operating temperature (-20ºC to 70ºC) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover Increased wiring space with 15mm and 20mm conduit knockout Improved LED status 24 VDC Backward compatibility with existing DH400 range, including remote accessories
    Details
  • Compatible with:; CRSO-WW-W1 CWSS-WR-W5 CWSS-WW-W5
    Details
  • Key Features:; Omni-directional light coverage eliminates need for device orientation. First fix capability allows electrical continuity testing prior to device fitting. Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. Positive fit engagement and feedback of base with device for easy installation.
    Details
  • Key Features:; Omni-directional light coverage eliminates need for device orientation. First fix capability allows electrical continuity testing prior to device fitting. Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. Positive fit engagement and feedback of base with device for easy installation.
    Details
  • Key Features:; Omni-directional light coverage eliminates need for device orientation. First fix capability allows electrical continuity testing prior to device fitting. Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. Positive fit engagement and feedback of base with device for easy installation.
    Details
  • Key Features:; Omni-directional light coverage eliminates need for device orientation. First fix capability allows electrical continuity testing prior to device fitting. Deep base option with multiple cable entries for flexible installation. Designed with full range of common fixing centres. Positive fit engagement and feedback of base with device for easy installation.
    Details
  • EN 54-3 and 54-23 compliant Synchronous sound and flash trigger Volume adjustable to 2 levels at the device C & W category Signal range up to 6.0 m room width for wall mounting Signal range up to 8.9 m room diameter for ceiling mounting
    Details
  • EN 54-3 compliant Suitable for 12 V and 24 V DC service voltage Synchronous sound trigger Volume adjustable to 2 levels at the device
    Details
  • Key Features:; Approved to EN54-3 Superior sound output and low current consumption 32 tones all approved to EN54-3 Adjustable volume settings Two stage sounders enable alert and alarm sequences to be set for phased evacuation Synchronised sound output
    Details
  • Key Features:; EN 54-3 compliant Suitable for 12 V and 24 V DC service voltage Synchronous sound trigger Volume adjustable to 2 levels at the device
    Details
  • Morley Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet
    Details
  • Small to medium-sized spaces up to 400 m² (e.g. IT areas, server rooms) Equipment (e.g. switch cabinets, telecommunications equipment) Up to 5 adjacent rooms with localisation of the source of the fire (e.g. hotel rooms, offices, prison cells) Stand-alone areas of application (e.g. wind farms, transformer stations) Cold stores/freezers
    Details
  • Small to medium-sized spaces up to 400 m² (e.g. IT areas, server rooms) Equipment (e.g. switch cabinets, telecommunications equipment) Up to 5 adjacent rooms with localisation of the source of the fire (e.g. hotel rooms, offices, prison cells) Stand-alone areas of application (e.g. wind farms, transformer stations) Cold stores/freezers
    Details
  • IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers
    Details
  • IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers
    Details
  • Key Features:; Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
    Details
  • Modern design Clip together assembly Weatherproof kit option High “ring” output; Suitable for all locations Easy to fit Provides protection up to IP44C with weather resistant option Easily identified signal