Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Datasheet Hochiki - User Manual Hochiki - Certificate of Conformity -
Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist ATEX certified to EEx d IIC T6 (85 C) (zones 1, 21, 2 and 22) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Leaflet Hochiki - Flame Detector - Installation Instructions -
Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours dust and mist ATEX certification to: EEx ia IIC T4 (135 C) (zones 0, 1 and 2) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - IS Detector - Brochure Hochiki - IS Detector - Installation Instructions Hochiki - IS Detector - Datasheet -
Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in ivory Approved by LPCB and GL SIL2 Approved variant available; Hochiki - Heat Detector - Datasheet Hochiki - Heat Detector - Installation Guide -
Key Features:; Class 1 performance as defined in BS EN54-10:2002 (range up to 25 m) Single IR technology Robust and slim design Low current consumption Easy to install Fits any of the CDX Range of mounting bases Twin LEDs for 360 degree viewing Approved by LPCB & VdS; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Installation Instructions Hochiki - Flame Detector - Leaflet -
Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB and GL SIL2 Approved variant available; Hochiki - IS Technology Guide Hochiki - Rate of Rise Detector - Specification Hochiki - Smoke Detector - Installation Guide Hochiki - Heat Detector - Datasheet Hochiki - IS Technology - Application Notes -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-HD - Data Sheet F-Guard UV-IR-HD - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; FLS-UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range FLS-UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR-F - Data Sheet F-Guard UV-IR-F - Operators Manual -
High immunity to false alarm Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions Hydrogen and Hydrocarbons flame detection High sensitivity -up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire HD video output with Automatic HD video recording of fire events. Data/ Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Ethernet communication -in addition to the standard methods, such as 4-20mA and Modbus Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels) Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector; UV-IR-HD: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0-micron range. UV-IR-F-HD: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0-micron range; F-Guard UV-IR-F-HD - Data Sheet F-Guard UV-IR-F-HD - Operators Manual -
Key Features:; Hydrogen and Hydrocarbons flame detection. Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions High sensitivity - up to 100ft (30m) for a 1ft2 (0.1m2) n-heptane pan fire High immunity to false alarm Data/Event logger - alarms, faults and other relevant events are logged to non-volatile memory. Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus. Built-in-Test (BIT) - Automatic and manual internal self-test of window cleanliness and the overall operation of the detector (for both IR and UV channels). Window heater to avoid condensation and icing. Tilt mounting bracket can be connected either above or below the detector. Configurable detection mode - allows configuration of UV-IR, UV or IR detection; UV-IR: Hydrogen and hydrocarbons flame detection. Spectrum response of IR radiation in the 3.0-4.0 micron range UV-IR-F: Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range; F-Guard UV-IR - Operators Manual F-Guard UV-IR - Data Sheet -
High immunity to false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire=High immunity to false alarm Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosion 1.2 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance HD video output with Automatic HD video recording of fire events. Data/Event logger: Alarms, faults and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3-HD - Data Sheet F-Guard IR3-HD - Operators Manual -
Key Features:; High immunity to a false alarm Extreme sensitivity -up to 260 ft. (80m) for a 1 ft2 (0.1m2) n-heptane pan fire Ultra-fast detection mode -detection within 40 milliseconds for fireballs or explosions 1.3 seconds detection time -for 1 ft2 (0.1m2) n-heptane pan fire at up to 50 ft. (15m) distance Data/Event logger -alarms, faults, and other relevant events are logged to non-volatile memory Built-in-Test (BIT) -Automatic and manual self-test of window cleanliness and the overall operation of the detector Window heater to avoid condensation and icing Tilt mounting bracket can be connected either above or below the detector.; F-Guard IR3 - Data Sheet F-Guard IR3 - Operators Manual