Approved to EN54-4 by VdS 2 and 5 amp versions Separate battery housing and connection lead available Energy efficient design based on switch mode technology Sturdy 1.2mm powder coated steel enclosure with a hinged lid finished in white -
Key Features:; Maximum range: 7 m -
Certified by UL to EN54-4:1997 +A1 +A2. Up to 1.2A current to load at 27.6V dc nominal regulated output. Charging capability to support 1.2 to 7Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit impedance (Ri) in excess of 500mW, caused by connector or wiring problem/corrosion, within 4 hours. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 1.2Ah 'T' Box Power Supply - 300h x 240w x 63d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1 +A2. Up to 1.2A current to load at 27.6V dc nominal regulated output. Charging capability to support 1.2 to 7Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit impedance (Ri) in excess of 500mW, caused by connector or wiring problem/corrosion, within 4 hours. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid -
Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 2A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply: 420h x 400w x 80d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid -
Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 5A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 38Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid -
Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 10 A current to load at 27.6V dc nominal regulated output. Charging capability to support 18, 38 or 65Ah batteries with intelligent load enhancement. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls to 21 V. Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present. RS232 serial interface for fault reporting and diagnostics interface to OEM equipment. Suitable to fit batteries up to 2 x 38Ah 'H' Box Power Supply - 420h x 420w x 180d Hinged Lid -
-
-
Fike Ocelus Conventional Standard Detector Base – 200-0014 -
Key Features:; Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection -
General Features:; 4 x 20mm gland entries. IP55 with supplied gasket. -
-
Key Features:; Robust metal housing. Twin fused outputs. Temperature compensated charging. Deep discharge protection of batteries. Fault relay output. Size 383mm wide x 408mm high x 97mm deep. Weight 4.3 Kg (excluding batteries). Supply voltage 230VAC 50/60Hz. Comprehensive LED status indication. -
Key Features:; Robust metal housing. Twin fused outputs. Temperature compensated charging. Deep discharge protection of batteries. Fault relay output. Size 383mm wide x 408mm high x 97mm deep. Weight 4.3 Kg (excluding batteries). Supply voltage 230VAC 50/60Hz. Comprehensive LED status indication. -
-
Key Features:; Robust metal housing Twin fused outputs Temperature compensated charging Deep discharge protection of batteries Fault relay output Comprehensive LED status indication -
Key Features:; Max Quantity per Loop – 100 Approx Weight – 0.34kg Operating Temperature – minus 10C to +50C Ingress Protection – IP40 Device Load Factor – 1 -
-
Key Features:; Ease of installation and a lot of space for wire connection Slide-easy base and elegant design with automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base One-way only fit -
Gent Conventional Relay Detector Base 805591; Provides a voltage-free contact controlled by the remote output of a detector Draws negligible current A lot of space for wire connection Automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base -
Key Features:; 3 continuously or pulsed LEDs Power-saving compact indicator -
Compatible with:; CRSO-WW-W1 CWSS-WR-W5 CWSS-WW-W5 -
-
Key Features:; Site selectable single or twin 24 V dc output 24 hour or 72 hour standby capability Fully monitored to EN54-4 Local LEDs for fast fault-finding Top or rear cable entry Space for up to 2 x 17Ah batteries -
-
-
-
-
-
Variants Available: -
-
Key Features; Battery Charger Monitored Fault Relay Output Low Battery Voltage Shutdown Reverse Polarity Protection Battery Charger Current Regulated LED indicators: AC ON, Battery & Charger Fault Boxed Unit inc. PSU and Battery Compartment Fully Compliant with EN54-4 -
Key Features; Battery Charger Monitored by Addressable Panel Fault Relay Output Relay O/P Remotely Controlled by Addressable Panel Low Battery Voltage Shutdown Reverse Polarity Protection Battery Charger Current Regulated LED indicators: AC ON, Battery & Charger Fault Boxed Unit inc. PSU and Battery Compartment Fully Compliant with EN54-4 -
Key Features; Battery Charger Monitored Fault Relay Output Low Battery Voltage Shutdown Reverse Polarity Protection Battery Charger Current Regulated LED indicators: AC ON, Battery & Charger Fault Boxed Unit inc. PSU and Battery Compartment Fully Compliant with EN54-4 -
Key Features; Battery Charger Monitored by Addressable Panel Fault Relay Output Relay O/P Remotely Controlled by Addressable Panel Low Battery Voltage Shutdown Reverse Polarity Protection Battery Charger Current Regulated LED indicators: AC ON, Battery & Charger Fault Boxed Unit inc. PSU and Battery Compartment Fully Compliant with EN54-4 -
-
-
-
-
-
Adapter is compatible with following call points:; GFE-MCPE-C conventional manual call point GFE-MCPE-A addressable manual call point GFE-MCPE-AI addressable manual call point with Loop isolator -
Red - Manual Call Point interface/ Micro Input Module Yellow - Micro Output Module/ Loop Sounder/ Beacon Controller White - Smoke/ Heat Detector interface. -
Red - Manual Call Point interface/ Micro Input Module Yellow - Micro Output Module/ Loop Sounder/ Beacon Controller White - Smoke/ Heat Detector interface.