  • Our Universal Hard Case Burn Kit allows you to be prepared for any burn emergency with a Burn Kit that offers the most popular combination of Burn Dressings and Burn Jel for large or minor burns. Item FSK-HA Sterile Burn Dressings: One 12" x 16" Two 4" x 4" Two 2" x 6" Dispenser Box of (25) Single-Dose Burn Jel Packets One Elastic Bandage One Instruction Card High-Impact Carry Case Case Pack: 5 kits Case Weight: 12.3 lbs. Case Size: 16in. x 12in. x 8in. (40.6 x 30.5 x 20.3 cm) Unit Dimensions: 9.94in. x 3in. x 7.25in. Unit Weight: 2.6 lbs.
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) Suitable for use in Zone 0,1 & 2 Robust GRP Body Suitable for offshore and petrochem Certificated Intrinsically Safe; Certification: CENELEC EN50014, 20 & 39 BAS02ATEX1258X EExia IIB T4 Zones 0,1 & 2 Material: UV stable glass reinforced polyester body. Clear polycarbonate cover/lens. Retained stainless steel cover screws. Finish: Painted Red Tube Type: Xenon discharge Lens Colour: Clear Terminals: 8 x 2.5mm2 Flash Rate: 1 flash per second Cable Entries: Up to 3 x M20 via knockouts Tube Energy: 0.5 Joules Weight: 1.4kg Certified Temperature: -55°C to + 60°C Ingress Protection: IP66 & IP67 Tube Life: >1 x 106 Flashes Voltage: 24V via suitable barrier Current Consumption: 71mA max nominal
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Robust Corrosion Resistant GRP body High Power (5 Joule) Certificated Flameproof; Voltage: 24Vdc Tube Energy: 5 Joules Peak Current Consumption (mA): 320 Effective Intensity (Cd): 29 Peak Intensity (Cd): 22213 Power Consumption (Watts): 8 Note: The Cd figures are for a clear lens @ 1Hz flash rate. For red lens multiple by 0.15 Weight: 2.5Kg Certified Temperature: EExd -55°C to + 70°C (T4) -55°C to + 55°C (T5) -55°C to + 40°C (T6) Ingress Protection: IP66 & IP67 Terminals: 6 x 2.5mm2 Entries: 2 x 20mm ISO EExd. Certification: BASEEFA EExd IIB 135°C (-55 to AMB +70°C)T4 100°C (-55 to AMB + 55°C)T5 85°C (-55 to AMB + 40°C)T6 Cert. No. 99 ATEX 2195X. CENELEC EN50014 and EN50018 Material Body: Glass reinforced polyester Lens: Glass Cover Screws + Backstrap: Stainless steel 316 Finish: Red
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Allows the 801/802/812/901 & 912 Sounder Base to become Addressable without the need to fit a Detector, thus creating an Addressable Loop Powered Sounder Suitable for wall or ceiling mounting Sounder Selection Tones as per 801/802/812/901 & 912 Sounder Base Fits the 801RB Relay Base to provide an Addressable Relay Base without the need to fit a Detector Colour matched to Sounder Bases Locked into Sounder Base using Detector Locking Pin SAM 800 is configurable in CONSYS SAB800 / SAB801 may be used with 5B or MUB bases SAB800 / SAB801 adds a Flashing Red Beacon facility to the 801/802/812/901 & 912 Sounder Base SAB801 Low current consumption (loop powered) SAB800 has two Modes of Operation - continuous or 2Hz flash, configurable in CONSYS SAB801 has two Modes of Operation - continuous or 1Hz flash , configurable in CONSYS
    Details
  • Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details
  • Key Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details
  • Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details
  • Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details