-
A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for pre alarm and class change Aesthetically pleasing rectangle wall mount option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic conventional bell tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Replace legacy LPSB3000 and LPAV3000 -
Long term service and support Two way IR communications with Generation 6 Detectors reduces commissioning and service costs. Supports 1 MZX Digital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership Wide range of multi-sensor detectors including the 3oTec triple sensing detections. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 "Critical" Matching 16 Zone Fully Functional Mains powered Repeater Approved to EN54 the system is designed to be installed to BS5839 -
Continuous detection despite extremely large monitoring area Easy and rapid installation of the maintenance-free sensor cable Very high resistance to extremely contrary ambient influences(immune against heat, cold, humidity, corrosion, strong winds and draft) Undiminished precision under electromagnetic interference Unprecedented security against false alarms Very high sensor cable service life of up to 30 years Temperature profile over the complete measurement range delivers exact information of location, size and spreading of the fire Very low maintenance costs as the maintenance and the trouble shouting can be done from the control unit VdS certified to EN 54/5-A1 One controller unit will drive up two 8km spurs or one 8km loop Easy integration into existing installations Each sensor cable divided into up to 256 zones Individual configuration of 5 alarm criteria per zone Good network connection through Modbus, TCP/IP, FTP and SCPI interfaces -
FIM800 field interface PCB incorporating one or two MZX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers LPCB, BV, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions -
EN54 Compliant MXDigital system Integral power supply Optional integral eighty way zonal LED’s Two to eight loops or network up to 396 loops 250 addresses per loop Full range of MZX virtual multi-sensor detectors MZX FASTLOGIC fuzzy logic smoke detection algorithms Fully functional repeater Powerful MXConsys & MXConsys Express configuration software Easy to install Space for 17Ah or 38Ah batteries -
PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions -
Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time -
Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time -
MX LPAV3000 Loop Powered Sounder/Beacon - Addressable Base; High output programmable sounder base and sounder beacon base One point of installation for detector, isolator, sounder & beacon Loop powered from the MX Technology® Digital Loop High brightness Multi-LED Beacon Software programmable 15 Tones and 2 Flash Rates Integral line isolator RSM (Reflective Sound Monitoring) Can be used as a standalone device using the sounder blanking cap -
-
MUBEX Base Installation & Commissioning Instructions