Approved for use in Class A, B and C, according to EN54-20 Provides Very Early Warning Fire Detection, as precise as 0.00095%/m obscuration Three alarm levels and three sensitivity modes provide application flexibility User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption Patented particle separator removes large, non-fire particulate, ensuring chamber health and extending the life of the field-replaceable filter Easy configuration via USB interface, no external power needed Configurable air flow fault thresholds and verification period Convenient wiring compartment -
Detection as precise as 0.0015%/m obscuration Integral Ethernet interface enables remote monitoring and e-mail status updates Patented particle separator and field-replaceable filter remove contaminants from the system Five alarm levels & two sensitivity modes Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement Protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions PipeIQâ„¢ software provides intuitive system layout, configuration, and monitoring all in one package Fault indictors covering a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications -
IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers -
IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers -
-
Please Note: the detector in the image above doesn’t come with the bracket and is for illustrative purposes only. -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps; Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook -
Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1 sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two 25 mm conduit entries or two ¾” NPT Low power consumption High RFI and EMI immunity FM hazardous area approved Ex d ATEX approved CU-TR approved INMETRO approved Meets SIL 2 requirements Certified to EN54-10:2002 (option) FM 3260 performance; Refineries and oil production facilities Off-Shore platforms Turbine/Compressor enclosures Acetylene processing and storage Oil and Gas pipelines and pumping stations LNG/LPG loading and unloading facilities Natural Gas and CNG plants Ethanol, Methanol, and IPA production and storage Crude oil and gasoline storage and tank farms Aircraft hangars Hydrogen plants and storage Paint and solvent storage Chemical production, storage, and loading facilities Power plants Silane gas storage; Morley FS20X-211-24-6 - Data Sheet Morley FS20X-211-24-6 - Installation Manual -
Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° field of view Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two M25 conduit entries Low power consumption; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide -
-
-
-
-
High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure -
High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure -
-
High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure -
A fully integrated and compact system, designed for larger pipe networks Designed for use in Honeywell Aspiration Smoke Detection ( ASD) systems Patented design without air resistance (as defined by EN 54-20) 6 user selectable preventive or event-triggered purging programs Internal clock or external clock timer can be connected Several systems can be coupled in Master-Slave mode Manual control via external push-button Automatic initiation if a fault message is received from the ASD system (activating through FACP only) Easy commissioning without software tools Multi-coloured LED indicates the system condition -
A fully integrated and compact system, designed for larger pipe networks Designed for use in Honeywell Aspiration Smoke Detection (ASD) systems Patented design without air resistance (as defined by EN 54-20) 6 user selectable preventive or event-triggered purging programs Short or long purging cycle options Internal clock or external clock timer can be connected Several systems can be coupled in Master-Slave mode Manual control via external push-button Automatic initiation if a fault message is received from the ASD system (activating through FACP only) Easy commissioning without software tools Multi-coloured LED indicates the system condition -