  • "Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"
    Details
  • "Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Eight detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • "Fike Ocelus Conventional 4 Zone Fire Panel “ 500-0004; Access via password “ removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies"
    Details
  • "Fike Ocelus Conventional 8 Zone Fire Panel “ 500-0008; Access via password “ removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies"
    Details
  • "Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs"
    Details
  • "Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface"
    Details
  • "Precept DC EN 16 Zone Repeater Panel with no Power Supply - 2605116 The 2605116 is a 16 Zone Precept Repeater Panel. The Precept Repeater Panel range can be 8, 16 or 32 Zone. The Precept AC range comes with a power supply whereas the Precept DC range doesn’t come with a power supply. The Precept Repeater Panel can range from 8, 16 or 32 Zone. As this Repeater Panel doesn't come with a power supply, it is powered from the Main Control Panel."
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • "Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
    Details
  • "Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
    Details
  • "Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
    Details
  • "Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
    Details
  • Key Features:; Dual Optical Detector Reduces False Alarms Omniview 360° LED Internal Alarm Current Limiting Resistor Wide Operational Voltage Range (16v-32v)
    Details
  • Installation:; Low profile, stylish appearance Different response grades available Non-polarised terminals Unauthorised head removal signal facility Low monitoring current Patented OMNIVIEW™ 360º LED alarm indicator Remote indicator output Compatible with UB-4, UB-4SD and STB-4SE bases
    Details
  • Key Features:; 62°C and 92°C Heat Detectors Omniview 360° LED Internal Alarm Current Limiting Resistor Wide Operational Voltage Range (11v-32v)
    Details
  • Optical Smoke Detector Omniview 360° LED S/C Alarm characteristic Wide operational voltage range (12v - 32v)
    Details
  • Low profile design Low current draw Automatic drift compensation Remote alarm trigger feature Easy maintenance Range of detector bases available Remote LED Option Approved to EN54–7:2000 (Amendment 1) EN54 – 5:2000 (Amendment 1) Class A1R; CEA 4021
    Details
  • Low profile design Low current draw Easy maintenance Range of detector bases available Remote LED Option Approved to EN54 – 5:2000 (Amendment 1) Class BS Remote alarm trigger feature
    Details
  • Low profile design Low current draw Automatic drift compensation Remote alarm trigger feature Easy maintenance Range of detector bases available Remote LED Option Approved to EN54–7:2000 (Amendment 1) EN54 – 5:2000 (Amendment 1) Class A1R; CEA 4021
    Details