Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller 5-year Warranty -
-
Approvals:- II 2 GD
- Ex db op is IIC T6 Gb
- Ex tb IIIC T85°C Db
- Ta = 20°C to +55°C
- Self check and automatic compensation
- Robust metal construction
-
II 2 GD Ex db op is IIC T6 Gb Ex tb IIIC T85°C Db Ta = 20°C to +55°C; 12 and 24V operation Explosion Proof Transmitter and Receiver Units Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordance stores; The Fireray® 3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. The Fireray® 3000 Exd optical beam smoke detector, together with a battery backed power supply, can be connected to a zone of a conventional fire alarm control panel or interfaced to an analogue addressable system via an addressable input module or a zone monitor module. -
Key Benefits- Allows for 2 Detectors per System Controller
- Range 5 to 120 metres, configurable per set of Detectors
- Integral Laser Alignment in Receiver
- 2-wire Interface between Controller and Receiver
- Seperate Fire and Fault Relays per Detector
-
-
-
12 and 24V operation Explosion Proof Transmitter and Receiver Units. Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordnance stores. -
-
Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction Conforms to: BS5839 Part 5 and EN54 part 12, UL and Vd -
Key Benefits- Single Compact Housing
- Area coverage 50 metre or 100 metre model available
- 12-24 Vdc Operation
- Low current Consumption
- Robust Construction
- Conforms to: BS5839 Part 5 and EN54 part 12, UL and VdS
-
Alarm Acknowledgement Sound Alarms Alarm Reset Alarm and Warning System Isolate Previous and Next – to scroll through faults and alarms; Key Features:; Up to 30 SmartTerminal’s can be connected to each FireFinder Fire Alarm Control Panel Large LCD with Backlight Internal Buzzer Flush or Surface Mountable Enclosure Control Enable Key Switch Controls have tactile and audible feedback Slimline version available -
Key Features:; Robust metal housing Twin fused outputs Temperature compensated charging Deep discharge protection of batteries Fault relay output Comprehensive LED status indication -
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support" -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support" -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support" -
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support" -
Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support -
Key Features:; From 2 to 32 zones (up to 32 detectors per zone). EN54-2 / CPD approval (BSI). Comprehensive end-user facilities (access level 2). Designed & built using the latest technology for optimum performance and consistently high quality. Extensive configurable facilities for the engineer via DIP switches. 4 alarm circuits as standard (4 zone panel and above). Up to 5 fully-functional repeaters - 2-wire RS485. Range of EN54 compliant power supply modules, designed to meet the specific load requirements of each size panel. Zonal one-man test feature and sounder one-man test facility. Short circuit to fire setting for use with older type detectors. Panel inputs for class change, evacuate, silence alarms, system reset. 3 open-collector outputs for evacuate, buzzer active, disablement active. Auxiliary supply output - monitored fuse. Optional timer clock/counter module. Optional foreign languages text insertable versions available. Optional semi-flush and fully flush mounting bezels available. -
EN54 approved Optional extinguishing module EN12094-1 approved 8 zones mainboard Supports 2 J400-EXP8 expander modules, for total 24 zones Up to 32 devices can be connected to each zone Gas zone compatible with 4-20 mA gas detectors One alarm-repeat output (open collector) for each input zone Manual call point recognition Signals missing detectors 2 supervised, silence able, by passable 24 V alarm output for sounders Silence able fault-warning output for the activation of signalling and auxiliary devices Supervised fire output for telephone dialler activation Programmable open-collector output Dry contact alarm-relay for the activation of auxiliary devices Day/Night mode Alarm verification time Programmable restoral and reset times Programmable from PC or keypad 50 event log viewed via PC Alarm/fault memory activated until next reset Command for silencing sirens Keypad commands require key or pin code Repeater available Optional backlit display -
Fully approved. Optional extinguishment module EN12094-1 approved. 8 zones mainboard. Supports 2 J400-EXP8 expander modules, total 24 zones. Up to 32 devices can be connected to each zone. Gas zone compatible with 4 – 20 mA gas detectors. One alarm-repeat output for each input zone. Manual call point recognition. Signals missing detectors. 2 supervised, silence able, bypass able 24 V alarm output for sirens and activation. Silence able fault warning output for the activation of signalling and auxiliary devices. Supervised fire output for telephone dialler activation. Programmable open-collector output. Dry contact alarm-relay for the activation of auxiliary devices. Day/Night mode. Alarm verification time. Programmable restoral and reset times. Programmable from PC or keypad. 50 event log viewed via PC. Alarm/fault memory activated until next reset. Command for silencing sirens. Keypad commands require key or pin code. Repeater available. Optional backlit display. -
Fully approved. Optional extinguishment module EN12094-1 approved. 8 zones mainboard. Supports 2 J400-EXP8 expander modules, total 24 zones. Up to 32 devices can be connected to each zone. Gas zone compatible with 4 – 20 mA gas detectors. One alarm-repeat output for each input zone. Manual call point recognition. Signals missing detectors. 2 supervised, silence able, bypass able 24 V alarm output for sirens and activation. Silence able fault warning output for the activation of signalling and auxiliary devices. Supervised fire output for telephone dialler activation. Programmable open-collector output. Dry contact alarm-relay for the activation of auxiliary devices. Day/Night mode. Alarm verification time. Programmable restoral and reset times. Programmable from PC or keypad. 50 event log viewed via PC. Alarm/fault memory activated until next reset. Command for silencing sirens. Keypad commands require key or pin code. Repeater available. Optional backlit display. -
Fully approved. Optional extinguishment module EN12094-1 approved. 8 zones mainboard. Supports 2 J400-EXP8 expander modules, total 24 zones. Up to 32 devices can be connected to each zone. Gas zone compatible with 4 – 20 mA gas detectors. One alarm-repeat output for each input zone. Manual call point recognition. Signals missing detectors. 2 supervised, silence able, bypass able 24 V alarm output for sirens and activation. Silence able fault warning output for the activation of signalling and auxiliary devices. Supervised fire output for telephone dialler activation. Programmable open-collector output. Dry contact alarm-relay for the activation of auxiliary devices. Day/Night mode. Alarm verification time. Programmable restoral and reset times. Programmable from PC or keypad. 50 event log viewed via PC. Alarm/fault memory activated until next reset. Command for silencing sirens. Keypad commands require key or pin code. Repeater available. Optional backlit display. -
-
-
IAS800 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two pipe runs. IAS801 single inlet pipe configuration which can be fitted with one detector.; Ideal for areas where access is restricted, harsh environments and areas where a point detector would be damaged Powerful Fan Up to two 100m pipe runs available Pipes can be individually monitored for air flow with LED bar graph FireClass loop and 24Vdc connections Fault monitored via the FireClass loop IP65 enclosure Field serviceable air filters Uses standard 25mm VESDA pipe and fittings -
IAS800 twin inlet pipe configuration which can be fitted with two detectors for monitoring one or two pipe runs. IAS801 single inlet pipe configuration which can be fitted with one detector.; Ideal for areas where access is restricted, harsh environments and areas where a point detector would be damaged Powerful Fan Up to two 100m pipe runs available Pipes can be individually monitored for air flow with LED bar graph FireClass loop and 24Vdc connections Fault monitored via the FireClass loop IP65 enclosure Field serviceable air filters Uses standard 25mm VESDA pipe and fittings -
8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Integral slot card cage – easily expanded with a number of slot card options? -
8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Integral slot card cage – easily expanded with a number of slot card options? -
8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Compact shallow housing or deep housing - designed for standard or extended battery standby period? -
8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Compact shallow housing or deep housing - designed for standard or extended battery standby period?