Key Features:; 1000 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level of each detector 10,000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes Up to 99 panels networkable Up to 7 fully functional repeaters available -
1000 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level of each detector 3000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes Up to 24 panels networkable Up to 7 fully functional repeaters available -
-
6 in 2 loops Up to 800mA current dynamically shared across 3 loop circuits Auto mapping with Intelli-Zone feature Online Help function USB interface dual role Host/Device Multi users and multi installers (Up to 2 installers, 8 users) Walk test function 4000 Event Log Loop break location On board PSTN communicator GSM/GPRS as external module Up to 8 repeaters and up to 7 FC500 Series panel clients Event transmission through PSTN and IP Automatic drift compensation Fast and simple system configuration, also offline Transferable user database Device graphic displayed Battery and wiring calculation Customizable cables database Visualization of all the devices assigned to a single zone Remote real time visualization of control panel loop and zone status, and so on. Easy remote user interface with control buttons (reset, silence, evacuate) Multilevel map based on a tree structure Access device data from any pages of the map Configuration downloadable to USB memory stick Capability to print zone label sheet for front panel customization -
3 in 1 loops Up to 800mA current dynamically shared across 3 loop circuits Auto mapping with Intelli-Zone feature Online Help function USB interface dual role Host/Device Multi users and multi installers (Up to 2 installers, 8 users) Walk test function 4000 Event Log Loop break location On board PSTN communicator GSM/GPRS as external module Up to 8 repeaters and up to 7 FC500 Series panel clients Event transmission through PSTN and IP Automatic drift compensation Fast and simple system configuration, also offline Transferable user database Device graphic displayed Battery and wiring calculation Customizable cables database Visualization of all the devices assigned to a single zone Remote real time visualization of control panel loop and zone status, and so on. Easy remote user interface with control buttons (reset, silence, evacuate) Multilevel map based on a tree structure Access device data from any pages of the map Configuration downloadable to USB memory stick Capability to print zone label sheet for front panel customization? -
3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation -
3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation -
3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation -
Multiple fire detection modes FireClass digital detection algorithms CO fire detection technology Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved -
Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved -
Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes Select the tone volume using panel configuration software Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes Select the tone volume using panel configuration software Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes Select the tone volume using panel configuration software Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic Conventional Bell Tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector -
Key Features:; A compact and discrete solution One point of installation for detector and sounder with no additional wiring Low power with up to 250 sounders on a single loop. Provides uncompromised system design solutions Simple to select the tone and volume using switches. No special training or tools needed 9 selectable tones 4 selectable volumes A locking pin supplied with the base which prevents the unauthorized removal of the detector Replaces FC430SB and it is compatible with FireClass addressable detectors -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Self-test Shorter Light Pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Self-test Shorter Light Pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution VAD approved to EN54-23 with two ranges, standard power and high power available High Power option provides a larger VAD coverage volume compared to Standard Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Self-test Shorter Light Pulse for faster response Optimise the system design for lowest power requirements and lowest cost installation Triple light source One point of installation for detector, sounder and visual indicator with no additional wiring Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar. Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VADs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Provides an EN54-23 approved upgrade path for legacy systems -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal -
A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic Conventional Bell Tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector -
-
Key Features:; Optional conduit entry backboxes Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection Optional short circuit isolator in each base Loop powered sounder bases -
Integral short circuit isolator. Dual colour LED indication. EN54-11 certification. Compact, modern styling. Test key for fast testing. IP67 ingress protection models for external applications. -
Integral LED indicator for easy identification of operation Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Hazardous area models available IP67 Waterproof models for external applications -
Integral Short Circuit Isolator Dual Colour LED Indication EN54-11 Certification Compact, Modern Styling Test Key for Fast Testing IP67 Ingress Protection models for external applications -
Integral LED indicator for easy identification of operation Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Hazardous area models available IP67 Waterproof models for external applications -
-
-
Up to 250 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level at point in alarm Viewing 3000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes -
-
-
"2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)" -