/All Products
  • "2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)"
    Details
  • 2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)
    Details
  • "Key Features:; 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)"
    Details
  • "Key Features:; 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)"
    Details
  • 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)
    Details
  • DPK6 for use with FC460PH with built-in 4B-C 4” continuity base. Designed to comply with EN 54-27. One-pipe air sampling system. Patented Cap-up Venturi pipe and duct housing. Test hole on cover. Simple installation. Sensitive flow indicator. Simple service and maintenance. Range of aluminium probe tubes are available for ducts up to 2700 mm.
    Details
  • Integral LED indicator for easy identification of operation Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Hazardous area models available IP67 Waterproof models for external applications
    Details
  • Distinctive and recognisable styling Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Optional Plastic Deformable Call Point Element for food processing areas IP67 Waterproof models for external application
    Details
  • Key Features:; Robust metal housing. Twin fused outputs. Temperature compensated charging. Deep discharge protection of batteries. Fault relay output. Size 383mm wide x 408mm high x 97mm deep. Weight 4.3 Kg (excluding batteries). Supply voltage 230VAC 50/60Hz. Comprehensive LED status indication.
    Details
  • Key Features:; Robust metal housing. Twin fused outputs. Temperature compensated charging. Deep discharge protection of batteries. Fault relay output. Size 383mm wide x 408mm high x 97mm deep. Weight 4.3 Kg (excluding batteries). Supply voltage 230VAC 50/60Hz. Comprehensive LED status indication.
    Details
  • Simplifies the wiring between Beam detector and FC410BDM Allows FC410BDM to be sited up to 40m from the beam detector
    Details
  • Features:; Reduced installation costs due to easier termination, polarity independent wiring and use of common base for all detector types Lower cost of ownership as no radioactive source disposal costs together with less spares holding Easier system design with full range of detector types including intrinsically safe models Higher safety in accommodation areas by using the unique Carbon Monoxide (CO) detection IP55 rated 60oC and 90oC fixed temperature heat detector
    Details
  • Key Features:; Aesthetically discreet Superior performance and reliability Adjustable Volume Control Selectable Tones Extra Low Current option Optional Sounder cap for standalone use Relay Base for local control
    Details
  • Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Integral and remote alarm LED Series of product approvals
    Details
  • Key Features:; Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Integral and remote alarm LED Series of product approvals
    Details
  • Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Integral and remote alarm LED Series of product approvals
    Details
  • Low profile, discreet and unobtrusive Superior performance and reliability Designed for fast, easy installation Series of product approvals; 601F Detector - Data Sheet
    Details
  • General Features:; 4 x 20mm gland entries. IP55 with supplied gasket.
    Details
  • Key Features:; Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection
    Details
  • New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place.
    Details
  • New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place. Five Times Faster: We have designed completely new linear stepper motors which have resulted in amazingly fast commissioning and routine maintenance. Under test conditions at 40 metres we recorded an auto-align time of 3m02s using the Fire Beam straight out of the box. Once aligned a routine re-alignment was timed at just 1m07s. This is class-leading performance not only in terms of speed but also in terms of advanced robust design built for precise purpose. Multi Language Support: The Fire Beam Xtra has the ability to display seven different languages: English, German, Spanish, French, Italian, Dutch, and Czech. A feature that is welcomed by our ever increasing international customers as we now sell to 62 countries around the world. Auto-Align On/Off: Although rarely needed, this facility allows you to turn off the auto-alignment in normal service, should the environment be liable to occasional contamination (such as theatres with fake smoke). As motorised beams work by seeing the reflector, if they are unable to because of unavoidable obscuration they can fall out of alignment when trying to find the obscured reflector. The Fire Beam Xtra will remain in perfect alignment in these environments simply by not trying to re-align itself. Auto-alignment will still continue to work in commissioning modes. This facility is best suited to beams that are mounted on solid surfaces that are not susceptible to building movement at all. For buildings that are liable to movement (such as metal warehouses) we have also built in a new delay function that can be used instead (see below). Auto-Align Time Delay: Again this facility is useful in environments that are liable to occasional short term obscuration. Adding a delay means that the beam will not check for alignment if the received signal drops for a predetermined time. Pre-set at 4 hours this can be altered to anywhere between 0 to 12 hours if required, to allow the environment to clear. Beam Phasing: It is possible that beams that face each other will cause problems as their sample rates could coincide and result in unreliable readings, meaning false auto-alignment and unreliably in service. With the introduction of phasing it is now possible to mount beams facing each other with reflectors in between. There are up to 7 different sampling rates to choose from, alleviating any cross talk problems. Hysteresis: Changing the hysteresis will change the delay in returning from a fire state back to a normal state. For example, the beam is factory set at 15% so if the beam falls into fire at 65% (35% threshold) it has to recover 15% to 80% before it returns to normal. This action prevents small fluctuations in returned signal causing the beam to fall in and out of a fire state. This can be adjusted to anywhere between 1% and 40%. The hysteresis can simply be adjusted from this new menu option. Up to 160 Metre Range: With new enhanced optics you can cover distances up to 160 metres, meaning for distances over 100 metres you no longer need to use two beams, saving both time and money. Very Low Power: using only 3.5mA any state opens up a whole world of options. In some cases you can loop power the beam, for instance using an Apollo xp95 mini switch monitor allows you do just that and turns the conventional Fire Beam into an addressable unit. IP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can't set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams all the moving optics are safely encased inside the waterproof enclosure so you won't accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment.
    Details