-
Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) 96 dB sounder (at 1 metre) Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D -
Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) Non-sounder Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D -
Spectrex 40/40 Series - Accessories -
Spectrex 40/40 Series - Accessories -
Spectrex 40/40 Series - Accessories -
Spectrex 40/40 Series - Accessories -
UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories -
Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories -
UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories -
UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories -
Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories -
Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories