Description; Marine grade, corrosion proof, LM6 aluminium enclosure Automatic synchronisation on multi-beacon system. Glass lens & Stainless Steel guard Very large termination area. Dual M20 cable entries – adaptors available. Stopping plug included. Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 120+160 candela effective light intensity. UV stable PC, field replaceable, colour lens filters.; 1Hz flash (60 fpm) 1.5Hz flash (90 fpm) 2Hz flash (120 fpm) Double strike flash Triple strike flash High Power Steady Low Power Steady; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure Automatic synchronisation on multi-beacon system. Beacons can be set to ‘flip-flop’ alternating mode with other units on multi-beacon systems. Xenon tubes mechanically secured against shock & vibration Glass lens & Stainless-Steel guard Very large termination area. Dual M20 cable entries – adaptors available. Stopping plug included. Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 120+120 candela effective light intensity. UV stable PC, field replaceable, colour lens filters.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure. Ingress protection IP66/67 Stainless steel fixings Dual M20 cable entries – adaptors available. Stopping plug included. Reverse polarity diode fitted. Automatic synchronisation on multi-sounder system. Very large termination area. Ratchet adjustable stainless steel ‘U’ bracket. ‘Stage Programmable’ version available with 45 tones & 4 remotely selectable stages.; Vimpex - Installation Manual Vimpex - Instruction Manual Vimpex - Datasheet -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure. Ingress protection IP66/67 Stainless steel fixings Dual M20 cable entries – adaptors available. Stopping plug included. Reverse polarity diode fitted. Automatic synchronisation on multi-sounder system. Very large termination area. Ratchet adjustable stainless steel ‘U’ bracket.; Vimpex - Installation Manual Vimpex - Datasheet -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure Ingress protection IP66/67 Automatic synchronisation on multi-beacon systems Choice of five flash rates: 1Hz, 1.5Hz, 2Hz, double and triple flash. High and low power Steady modes Three remotely selectable stages/channels on DC versions. Glass lens & Stainless Steel guard UV stable PC field replaceable lens colour filter Dual M20 cable entries – adaptors available. Stopping plug included. Duplicate cable terminations (in & out for daisy-chain installations) Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 160 candela effective light intensity. ‘Stage Programmable’ version available with 45 tones & 4 remotely selectable stages.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure Automatic synchronisation on multi-beacon & sounder systems. Beacons can be set to ‘flip-flop’ alternating mode with other units on multi-beacon systems. Xenon tubes mechanically secured against shock & vibration Very large termination area. Dual M20 cable entries – adaptors available. Stopping plug included. Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 120 candela effective light intensity. UV stable PC, field replaceable, colour lens filters. ‘Stage Programmable’ version available with 45 tones & 4 remotely selectable stages.; Vimpex - Installation Manual Vimpex - Datasheet -
Description; Omni-directional sound output. Marine grade, corrosion proof, LM6 aluminium enclosure. Ingress protection IP66/67 Stainless steel fixings Dual M20 cable entries – adaptors available. Stopping plug included. Reverse polarity diode fitted. Automatic synchronisation on multi-sounder system. Very large termination area. Ratchet adjustable stainless steel ‘U’ bracket.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure Omni-directional sound output. Automatic synchronisation on multi-beacon & sounder systems. Beacons can be set to ‘flip-flop’ alternating mode with other units on multi-beacon systems. Very large termination area. Dual M20 cable entries – adaptors available. Stopping plug included. Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 160 candela effective light intensity. UV stable PC, field replaceable, colour lens filters. ‘Stage Programmable’ version available with 45 tones & 4 remotely selectable stages.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Omni-directional sound output. Marine grade, corrosion proof, LM6 aluminium enclosure Automatic synchronisation on multi-beacon & sounder systems. Beacons can be set to ‘flip-flop’ alternating mode with other units on multi-beacon systems. Xenon tubes mechanically secured against shock & vibration Very large termination area. Dual M20 cable entries – adaptors available. Stopping plug included. Ratchet adjustable stainless steel ‘U’ bracket. Reverse polarity diode fitted. IP66/67 ingress protection. 120 candela effective light intensity. UV stable PC, field replaceable, colour lens filters. ‘Stage Programmable’ version available with 45 alarm tones and 4 remotely selectable stages.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Automatic synchronisation on multi-sounder system. Very large termination area. Ratchet adjustable stainless steel ‘U’ bracket. IN & OUT terminals. Independently selectable tones for 1st & 2nd stages. Four remotely switched stages/channels. SIL1 compliant to IEC61508 (2010).; GNEXS1DC024 - 17 dbA GNEXS2DC024 - 24 dbA; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Robust, corrosion proof GRP (glass reinforced polyester) enclosure Ingress protection IP66 Automatic synchronisation on multi-beacon systems Choice of five flash rates: 1Hz, 1.5Hz, 2Hz, double and triple flash. High and low power Steady modes Three remotely selectable stages/channels on DC versions. Glass lens & Stainless-Steel guard UV stable PC field replaceable lens colour filter Stainless steel fixings Triple cable entries Duplicate cable terminations (in & out for daisy-chain installations) SIL1 compliant to IEC61508 (2010); Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010) Complies with design requirements of EN54-11; Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Stainless Steel lift flap Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Installation Manual Vimpex - Installation Manual (1) -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010) Complies with design requirements of EN54-11; Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Stainless Steel lift flap Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Installation Manual (1) Vimpex - Installation Manual (2) -
Description; ATEX certificate: Sira 09ATEX3286X, IECEx certificate: IECEx SIR 09.0121X, SIL 2 certified to IEC 61508 (2010) Ex EAC certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. DIN rail mounted terminal blocks: 8 × 2.5mm². Metalised polyester or stainless steel “Duty” label. Series and/or End of Line resistors, diodes & Zener diodes Indicator LED.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X SIL 2 certified to IEC 61508 (2010) Ex EAC certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. Metalised polyester or stainless steel “Duty” label.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X, IECEx certificate: IECEx SIR 09.0121X, INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010); Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Installation Manual Vimpex - Installation Manual (2) -
Description; ATEX certificate: Sira 09ATEX3286X, IECEx certificate: IECEx SIR 09.0121X, INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010); Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Installation Manual Vimpex - Installation Manual (2) -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X SIL 2 certified to IEC 61508 (2010) Ex EAC certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. Metalised polyester or stainless steel “Duty” label.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X, IECEx certificate: IECEx SIR 09.0121X, INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010); Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X SIL 2 certified to IEC 61508 (2010) Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. DIN rail mounted terminal blocks: 8 × 2.5mm². Metalised polyester or stainless steel “Duty” label. Series and/or End of Line resistors, diodes & Zener diodes Indicator LED.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Alternative housing colours are available to meet specific requirements. DIN rail mounted terminal blocks: 8 × 2.5mm² Metalised Polyester “Duty” label. Series and/or End of Line resistors.; ATEX certificate: Sira 09ATEX3286X, IECEx certificate: IECEx SIR 09.0121X, INMETRO certificate: 10-IEx-0011X Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271 SIL 2 certified to IEC 61508 (2010); Vimpex - Datasheet Vimpex - Installation Manual Vimpex - Installation Manual (2) -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X SIL 2 certified to IEC 61508 (2010) Ex EAC certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. Metalised polyester or stainless steel “Duty” label.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; Marine grade, corrosion proof, LM6 aluminium enclosure Ingress protection IP66/67 Choice of five flash rates: 1Hz, 1.5Hz, 2Hz, double and triple flash. High and low power Steady On modes Three remotely selectable stages/channels on DC versions. Glass lens & Stainless-Steel guard UV stable PC field replaceable lens colour filter Stainless steel fixings Dual cable entries Duplicate cable terminations (in & out for daisy-chain installations) Ratchet adjustable stainless steel ‘U’ bracket.; Vimpex - Datasheet Vimpex - Installation Manual -
Description; ATEX certificate: Sira 09ATEX3286X IECEx certificate: IECEx SIR 09.0121X SIL 2 certified to IEC 61508 (2010) Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271; Alternative housing colours are available to meet specific requirements. Single or double pole c/o switch. DIN rail mounted terminal blocks: 8 × 2.5mm². Metalised polyester or stainless steel “Duty” label. Series and/or End of Line resistors, diodes & Zener diodes Indicator LED.; Vimpex - Datasheet Vimpex - Installation Manual -
Robust, corrosion proof GRP (glass reinforced polyester) enclosure Ingress protection IP66 Automatic synchronisation on multi-beacon systems DC voltage versions feature a choice of three flash rates DC voltage units feature remote initiation of flash rate User replaceable Xenon tube mechanically secured against shock & vibration Glass lens & Stainless-Steel guard UV stable PC field replaceable lens colour filter Stainless steel fixings Dual cable entries Duplicate cable terminations (in & out for daisy-chain installations) SIL1 compliant to IEC61508 (2010); Vimpex - GNEXB - Datasheet Vimpex - GNEXB - Installation Manual -
Input overload and reverse current protection Prismatic lens optimises L.E.D effectiveness Marine grade aluminium enclosure Auto synchronised sound output External mounting lugs Duplicate cable terminations(in & out for daisy-chain installations). Available with custom tone configurations and frequencies.; IS-DL105L-R/B - Blue Lens IS-DL105L-R/R - Red Lens; Vimpex - Installation Manual Vimpex - Datasheet -
IS FlashDome - Data Sheet -
Alternative housing colours are available to meet specific requirements. Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Part A Instruction Manual Vimpex - Part B Instruction Manual -
Alternative housing colours are available to meet specific requirements. Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Part A Instruction Manual Vimpex - Part B Instruction Manual -
Input overload and reverse current protection End of line resistor certified Auto synchronised sound output Available with custom tone configurations; Vimpex IS-MA1M-R - Installation Manual Vimpex IS-MA1M-R - Datasheet -
Product Details; 100dB(A) alarm sounder Approvals include ATEX, IECEx and GOST-R Zone 0 applications and FM approval for class Division 1 and class; Vimpex IS-MA1-R - Datasheet Vimpex IS-MA1-R - Installation Manual -
Key Features; Input overload and reverse current protection Auto synchronised sound output Unit can be mounted using external lugs or internal BESA compatible fixing positions. Duplicate cable terminations (in & out for daisy-chain installations). Available with custom tone configurations and frequencies.; Vimpex IS-A105N-R - Datasheet Vimpex IS-A105N-R - Installation Manual -
Input overload and reverse current protection Marine grade aluminium enclosure Auto synchronised sound output External mounting lugs Duplicate cable terminations (in & out for daisy-chain installations). Available with custom tone configurations and frequencies. Choice of 49 alarm tones; Vimpex IS-D105-R - Installation Manual Vimpex IS-D105-R - Datasheet -
Key Features; Input overload and reverse current protection End of line resistor certified Auto synchronised sound output Prismatic lens optimises L.E.D effectiveness Available with custom tone configurations and frequencies; IS-MC1-R/A - Amber lens IS-MC1-R/B - Blue lens IS-MC1-R/C - Blue lens IS-MC1-R/G - Green lens IS-MC1-R/R - Red lens; Vimpex IS-MC1 - Datasheet Vimpex IS-MC1 - Installation Manual -
Alternative housing colours are available to meet specific requirements. Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Part A Instruction Manual Vimpex - Part B Instruction Manual -
Alternative housing colours are available to meet specific requirements. Metalised Polyester “Duty” label. Series and/or End of Line resistors.; Vimpex - Datasheet Vimpex - Part A Instruction Manual Vimpex - Part B Instruction Manual -
IS-CP4A-BG – A type – no end of line devices IS-CP4B-BG – B type – choice of end of line devices; Vimpex - Instruction Manual Vimpex - Datasheet -
IS-CP4A-BG – A type – no end of line devices IS-CP4B-BG – B type – choice of end of line devices; Vimpex - Instruction Manual Vimpex - Datasheet -
Key Features:; Automatic synchronisation on multi-sounder system. High output Xenon beacon DC voltage units feature multiple flash rates. Continuously rated. Stainless steel fixings. Unit can be mounted using external lugs or internal BESA compatible fixing positions. Duplicate cable terminations (in & out for daisy-chain installations). Tropicalisation available on request. Available with custom tone configurations and frequencies. ‘Programmable’ version available:; Industrial Sounder Beacon - Installation Sheet Industrial Sounder Beacon - Data Sheet -
Key Features:; Automatic synchronisation on multi-sounder system. High output Xenon beacon DC voltage units feature multiple flash rates. Continuously rated. Stainless steel fixings. Unit can be mounted using external lugs or internal BESA compatible fixing positions. Duplicate cable terminations (in & out for daisy-chain installations). Tropicalisation available on request. Available with custom tone configurations and frequencies. ‘Programmable’ version available:; Industrial Sounder Beacon - Data Sheet Industrial Sounder Beacon - Installation Sheet -
Features; Automatic synchronisation on multi-sounder system. High output Xenon beacon DC voltage units feature multiple flash rates. Continuously rated. Stainless steel fixings. Unit can be mounted using external lugs or internal BESA compatible fixing positions. Duplicate cable terminations (in & out for daisy-chain installations). Tropicalisation available on request. Available with custom tone configurations and frequencies. ‘Programmable’ version available:; Industrial Sounder Beacon - Data Sheet Industrial Sounder Beacon - Installation Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; EXD Beacon - Data Sheet -
Klaxon EXD Beacon, Amber 10W LED Lens, 100-240v AC; - TCB-0014; Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet -
Approved by ATEX and CQST • IMETRO and IECEX (Pending) ATEX: II 2G Exd IIC T4 - T6 (incorporating IIA & IIB) Zones 1&2, Zones 21&22 (Pending) Conforms to EN (IEC) 60079-0 EN (IEC) 60079-1 and EN54 360 degree light output around the vertical axis Dustproof & Weatherproof; Exd Beacon - Data Sheet