/All Products
  • User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing - green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB & VdS approved to Classes A1 & C SIL Level 2 approved variants available
    Details
  • Incorporates Optical & Heat elements Removable, High Performance Chamber Twin fire LED's allow 360° viewing Polling LED's controlled from Panel Variable sensitivity Electronically Addressed Approved to EN54 Part 5 & 7
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree viewing - green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB & VdS approved to Classes A, B & C SIL Level 2 approved variants available
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin LEDs allow 360 viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB & VdS approved to Classes A1, B & C SIL Level 2 approved variants available Available in white; Improvements:; New Outer Cover Design featuring indicative sensor type markings Software Advances Increased Noise Immunity Fully backwards compatible
    Details
  • Simple installation onto standard DIN railing Simplified installation and maintenance using plug-in connectors Input circuit protected against reverse polarity; Hochiki - Galvanic Isolator - Datasheet
    Details
  • Simple installation onto standard DIN railing Removable colour-coded terminals for easy connection Accommodates conductors up to 2.5 sq mm Supports up to two zones of I.S. products Enclosure (box) available - DX070; Hochiki - Zener Barrier - Datasheet
    Details
  • Complies with EN54-11 Push-fit terminals can accommodate up to a 2.5mm2 solid conductor Unique ‘Plug & Play’ installation concept Re-settable operating element option Resistive and clean contact connections Semi-flush or surface mounting Backward compatibility Approved by GL
    Details
  • 4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to both ivory and white detector ranges Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-2)
    Details
  • Key Features:; 4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to both ivory and white detector ranges Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-2)
    Details
  • 4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to white detector range Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-1)
    Details
  • 4 cable entry holes suitable for cable glands (2 glands supplied) Colour matched to ivory detector range Approved Sensor and Base range Provides moisture and dust resistant fixing Ideal for bulk-head fixing Approved by LR and GL Non-marine use version available (SBB-1)
    Details
  • Key Features:; Integral remote indicator output Low Profile, only 8 mm Rugged design Electronics free Quick connections via square cable clamps Accepts 2.5 mm cables Bayonet slot, low insertion force for detectors Approved to MED by GL GL Type approval
    Details
  • Approved to MED by GL Removable, High Performance chamber Twin LEDs allow 360° viewing – green when polling, red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & VdS
    Details
  • Removable, High Performance chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB EN54: Part 7, LR & GL SIL Level 2 approved variant available
    Details
  • Removable, High Performance chamber Twin fire LED's allow 360° viewing Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel*1 Approved by LPCB, LR & GL Available in ivory, white or black
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL Available in ivory
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available Available in ivory
    Details
  • Key Features:; User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree ° viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • Class 1 performance as defined in BS EN54-10:2002 (range up to 25 m) Single IR technology Robust and slim design Low current consumption Easy to install Fits the CDX marine-approved standard base Twin LEDs for 360° view Approved by LPCB & VdS Approved to MED by GL SIL Level 2 approved variants; Coal handling plant Aircraft hangars Automotive industry - spray booths, parts manufacture Pharmaceutical Engine rooms Waste handling Power plants Transformer stations Petrochemical
    Details
  • Key Features:; Electronic linear heat detection Remote indicator output Wide voltage range (9.5 ~ 30 V dc) Twin fire LEDs allow 360 degree viewing Approved by LPCB Approved to MED by GL GL Type approval
    Details
  • Electronic linear heat detection Remote Indicator output Wide voltage range (9.5 ~ 30 V dc) Twin fire LEDs allow 360 degree viewing Approved by LPCB Approved to MED by GL GL Type approval
    Details
  • Key Features; 24 V dc Surface mounted 200 Newton holding force Swivel keeper plate Spring-loaded ejector pin Manual release button
    Details
  • Loop Powered Single Loop Address - addressed via the TCH-B100 Hand Held Programmer Variable Sound Output 90 ~ 102 dB(A) (+/-2 dB(A)) output at 1 metre Fits Hochiki Standard or Isolator Base Weatherproof Kit available 51 User-Selectable Tones (all tones EN54-3 compatible) Also available in red Approved by LPCB & VdS
    Details