/Uncategorised
  • Key Features:; Proven reliability with a feature set that offers significant benefits to the customer Certified to EN54 Part 11 Single Pole Key removable in both positions
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • The ID61 is housed in a slightly larger enclosure (500mm x 400mm x 110mm) than the ID60 to accommodate for an internal mounted printer. A larger separate power supply (3A) is fitted in the ID61 to cater for the more power hungry applications.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • With A compact enclosure (380mm x 365mm x 110mm) and a single PCB with on-board power supply (1.5A), the ID60 provides the user with an easy to install/maintain Fire Alarm System.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
    Details
  • Key Features:; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS
    Details
  • Key Features; 2-8 Analogue Addressable Loops; each of up to 198 devices 255 Fire zones per panel Fully approved peer to peer network of up to 63 panels; maintains 3 second call point response time over the network Flexible timer functions; system sensitivity and functionality can be tailored for the time of day, or day of week Sophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems. Convenience features for commissioning and maintenance engineers such as auto-learn of loops, walk test and double address detection. CPD approved by LPCB (BRE) & VdS; 1 x 020-538 - Basic Equipment kit 2-8 loops 3 x 020-588 - Dual loop board kit 1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable 1 x 020-543 - Dual transmission path board kit 1x 020-548 - Optional status indicator board kit for 7A PSU 1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H:620mm W:500mm D:122mm. 1 x 020-480-009 - Main cover kit 1 x 020-481-009 - Extension cover kit 1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer 1 x 020-541-009 - 7A PSU/78AH battery cabinet kit
    Details