/Uncategorised
  • 12 and 24V operation Explosion Proof Transmitter and Receiver Units. Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordnance stores.
    Details
  • II 2 GD Ex db op is IIC T6 Gb Ex tb IIIC T85°C Db Ta = 20°C to +55°C; 12 and 24V operation Explosion Proof Transmitter and Receiver Units Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordance stores; The Fireray® 3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. The Fireray® 3000 Exd optical beam smoke detector, together with a battery backed power supply, can be connected to a zone of a conventional fire alarm control panel or interfaced to an analogue addressable system via an addressable input module or a zone monitor module.
    Details
  • Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller 5-year Warranty
    Details
  • Up to 2 optical beam detectors per system controller Easifit Fix System Ground Level Control Laser Assisted Alignment Auto-Optimise Beam Alignment Contamination Compensation Building Shift Compensation Approved to EN54:12 and UL268
    Details
  • Up to 2 optical beam detectors per system controller Easifit Fix System Ground Level Control Laser Assisted Alignment Auto-Optimise Beam Alignment Contamination Compensation Building Shift Compensation Approved to EN54:12 and UL268
    Details
  • 5 to 100 m range Automatic compensation Automatic signal strength adjustment Emitter unit can be powered directly from zone (or loop) Features a Latching or Non-Latching Fault Relay Can be interfaced onto ESP system via a CHQ-DZM or CHQ-SZM Full line continuity options Approved by LPCB & VdS
    Details
  • Combined transmitter and receiver unit Unique servo-operated test filter (6500RS) Range 5-100m 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Complies to EN54-12:2002 Extended warranty
    Details
  • Combined transmitter and receiver unit Unique servo-operated test filter (6500RS) Range 5-100m 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Complies to EN54-12:2002 Extended warranty
    Details
  • Combined transmitter and receiver unit Range 10-100 metres using the long range reflector kit 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-Red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom ±10° horizontal and vertical beam alignment Automatic drift compensation Loop powered Complies to EN54-12 Extended Warranty
    Details
  • 5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
    Details
  • 5 – 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop powered with built in isolation for system mapping Utilizes the advanced Opal digital protocol whilst remaining backward compatible with existing Notifier system The NFXI-BEAM-T Beam Detector features a unique remote test capability that fully tests both the optics and the electronics of the device. This means there’s no need to hire a platform to give high level access to the device in testing. Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity level
    Details
  • Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Low Power Usage Cost Effective
    Details
  • Infra-Red Transmitter and Receiver Technician Friendly Simple Menu System Protec Algo-Tec™ 6000 Protocol Low Power Usage FAST™ Addressing Cost Effective
    Details
  • Unique servo-operated test filter Combined transmitter and receiver unit Range 5-100m (with the long-range reflector kit) 4 x fixed sensitivity/threshold levels 2 x automatic variable sensitivity modes Operates in the Infra-red light spectrum Numerical indicators to aid beam alignment Standby, fault and alarm LED indicators visible from the front and bottom Automatic drift compensation Uses the Series 200 Advanced Protocol Loop powered Complies to EN54-12:2002 Extended warranty
    Details
  • Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller Supply voltage: 12-36VDC Current: Controller 14mA, per transmitter head 8mA Fire and Fault relays per detector head - rated 2A 30VDC Detector head dimensions per transmitter and receiver unit (mm): 74w x 74h x 161d Controller dimensions (mm): 203w x 124h x 73d
    Details
  • Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller
    Details
  • Single installation and maintenance point Fully addressable 100 metre detection range Unique simple alignment Selectable alarm thresholds Latching or auto reset fire output Automatic contamination compensation
    Details
  • Single installation and maintenance point Fully addressable 50 metre detection range Unique simple alignment Selectable alarm thresholds Latching or auto reset fire output Automatic contamination compensation
    Details
  • EN54/CPD approved Building Shift Compensation 2-wire Interface from Detector to System controller Laser Assisted Alignment Automatic Contamination Compensation Auto Alignment
    Details