‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four ‘individually identifiable’ sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. Multifunction Quarter VGA back lit LCD and programmer. May be networked with other Cirrus Pro Series aspirating detectors -
Unique Cloud Chamber Detection Principle Easy to Operate Completely Self Contained Locate potential fire threats from early warning alarms May be used in conjunction with any fixed air sampling system Multi-function LCD Display 10 Sensitivity Settings 4 Alarm Levels Fault diagnostic feature Includes sample probe and battery charger Immune to dust, humidity and temperature changes -
Cirrus Pro Series Remote Display Programmer. Multifunction Quarter VGA back lit LCD and programmer. Remote detector ‘Silence’ and ‘Reset’ buttons. May be networked with other Cirrus Pro Series aspirating detectors. -
Protec Algo-Tec 6000PLUS Protocol Ideal for detecting shouldering fires Devices display address numbers Easy to address FAST addressing Reduce false alarms -
Fast response thermistor Integrated electronic sounder Integrated high intensity LED beacon Loop powered Low current Programmable volume control Integral short circuit isolator Devices display address number -
Key Features:; Ideal where smoke detection is unsuitable Fast response thermistor Integrated electronic sounder Loop powered Low current Programmable volume control Integral short circuit isolator Sounder tone selectable at control panel Devices display address number -
Ideal where smoke detection is unsuitable Fast response thermistor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered Low current Programmable volume control Integral short circuit isolator Devices display address number -
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Electronic Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing Reducing False Alarm VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Key Features:; Dual technology sensor Combined smoke and heat sensors Ideal for multi-purposes Independent channel controls Day / night operation Protec Algo-Tec 6000PLUS Protocol Devices display address number Fast addressing Reduce false alarms -
Dual technology sensor Combines smoke and heat sensor Ideal multi-application sensor Integrated high intensity LED beacon Low powered Low current Integral short circuit isolator Devices display address number FAST addressing and reduces false alarms -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number FAST addressing and reduced false alarms -
Dual technology sensor Combines smoke and heat sensor Ideal multi-application sensor Integrated electronic sensor Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator -
Sensor VAD; -; Dual Technology Sensor Combined Smoke and Heat Sensor Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Integral Short Circuit Isolator Devices Display Address Number VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Key Features:; Multiple technology sensors Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Day / night operation Protec Algo-Tec 6000PLUS protocol Devices display address number FAST addressing Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated high intensity LED beacon Loop powered / low current Integral short circuit isolator Devices display address number FAST addressing Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Protec Algo-Tec 6000PLUS Protocol Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Unprecedented false rejection -
Multiple technology sensor Combined smoke, heat and CO sensors Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator -
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
1 - 4 Individual detectors per aspirator (providing up to 4 separately identifiable areas) High performance optical ‘Scatter Chamber Detectors’ (SCD) or High performance optical ‘Scatter Chamber Detectors’ (SCD) and enhanced CO detection Multiple language, multi-function LCD display Simple install and commission process without the need for a laptop connection Simple Class A, Class B, Class C and Prison sensitivity configuration set up Inbuilt algorithm to avoid unwanted alarms Airflow monitoring per pipe; Class A - High Sensitivity Applications include: Small Computer Rooms, Cleanrooms, Data Centres, Control Rooms, Archive Storage & EDP areas Class B - Enhanced Sensitivity Applications include: Small Historic Buildings, Museums, Theatres, Galleries, High Ceiling Areas, Small Clean Warehouses & Small Atria Areas Class C - Normal Sensitivity and Harsh Environment Applications include: Lift/Elevator Shafts, Small Cold Storage Facilities, Clean Warehouses, Atria, Inaccessible Voids & Up to 4 x separately identifiable Prison Cells per aspirator. -
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume