/Uncategorised
  • Key Features:; Compatible with Ziton addressable fire panels Connection layout with easy wiring and connection on installation Powered directly from the ZP loop for small installations, or externally when many units are required Fully addressable LED technology for long service life and low current consumption, maximising the number of devices on a loop Unique optics for light management with a lens design that optimises light dispersal, minimising power wastage Up to 7.5m coverage diameter, reducing the number of devices required to cover an area Coverage switch feature - for smaller areas switch down from 7.5m to 2.5m, reducing power consumption and saving up to 50% Flash rate switch feature, reducing the power consumption by up to 50% Soft start up for reduced current peak at start up, reducing circuit loading Locking base to prevent easy removal of device 8 Selectable tones with 4 selectable output levels IP66 rated for ingress protection in harsh environments EN54-3 and EN54-23 approved and CPR certified
    Details
  • A value of 1 (=Sounder fault) this means there was no sound detected in 5 seconds of the sounder being switched on. A value of 2 (=VAD fault) means there is no current being drawn by the LED’s. A value of 3 (=Sounder and VAD fault) where neither of the above elements are operating correctly.; EN54-23 approved Flash rate of 0.5Hz Synchronisation of 'alert' and 'evacuate' tones Synchronisation of visual indicator flash Individual and group addressing Unique acoustic and VAD self-test Built in isolator
    Details
  • EN54-23 approved Flash rate of 0.5Hz Synchronisation of VAD flash Individual and group addressing Unique VAD self-test Loop-powered Built in isolator
    Details
  • Third-party certified to EN54-3 (Sounders) and EN54-17 (Isolators) by Intertek (pending) Impressive 90dB(A) sound output @ 1m Onboard short-circuit loop isolator 5mA alarm current @24V DC (sounder on max) Attractively finished in red polycarbonate Group addressing facility allows multiple devices to be operated simultaneously 7 selectable volume levels and up to 15 selectable tone pairs Attractive compact design - just 102mm diameter, 63mm deep Includes an integrated sounder to base locking mechanism IP21C rated Low current consumption means multiple devices can be connected to the loop DIP switch addressed Simple ‘click and twist’ design and easy-fit base ensures rapid installation time Also available in a white plastic housing (order code BF450A/CX/SW)
    Details
  • Loop Powered Single Loop Address - addressed via the TCH-B100 Hand Held Programmer Variable Sound Output 90 ~ 102 dB(A) (+/-2 dB(A)) output at 1 metre Fits Hochiki Standard or Isolator Base Weatherproof Kit available 51 User-Selectable Tones (all tones EN54-3 compatible) Also available in white Approved by LPCB & VdS
    Details
  • Loop Powered Single Loop Address - addressed via the TCH-B100 Hand Held Programmer Variable Sound Output 90 ~ 102 dB(A) (+/-2 dB(A)) output at 1 metre Fits Hochiki Standard or Isolator Base Weatherproof Kit available 51 User-Selectable Tones (all tones EN54-3 compatible) Also available in red Approved by LPCB & VdS
    Details
  • Please Note: This item does not include a sounder.
    Details
  • Employs fully digital Hyfire protocol Built in loop isolators Fully Intelligent Selection of 32 tones Synchronised sounder Adjustable volume output Auto-addressable Programmable via Device Programming Tool Compatible with all Altair detectors 5-year product warranty Includes device identification tab Easy central cable entry
    Details
  • Employs fully digital Hyfire protocol Built in loop isolators Offers full programming options Selection of 32 tones Synchronised sounder 360 degree visibility of VID when activated Adjustable volume output Auto-addressable via compatible panels Programmable via the Device Programming tool 5 year product warranty Includes device identification tab Easy central cable entry
    Details
  • EN54-23 certified Flash rate of 0.5Hz It is possible to set individual volume of the sounder from the panel 15 pairs of tones including IMO code 1A 'General Emergency Alarm' and IMO Code 2 'All Clear' Built in isolator; Brand Information
    Details
  • 802SB Loop Powered Sounder Base Minerva MX; Manufactuered to EN54 part 3 Integral Sounder and Detector Base Volume and tone adjustable after installation Low Power Synchronisation Does not require use of a standard base (maybe installed directly onto a standard besa box)
    Details
  • Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
    Details
  • Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
    Details
  • 2 or 4 zone Twin Wire selection by DIL switch Approved to EN54-2 & 4 3 year warranty as standard Simple colour coded buttons for controls and programming Integral 1 amp switch mode PSU Class change & alert inputs Fire & fault relays 2 monitored sounder circuits Test mode Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
    Details
  • 2 or 4 zone Twin Wire selection by DIL switch Approved to EN54-2 & 4 3 year warranty as standard Simple colour coded buttons for controls and programming Integral 1 amp switch mode PSU Class change & alert inputs Fire & fault relays 2 monitored sounder circuits Test mode Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
    Details
  • Can be used with 2, 4 and 8 zone control panels Internal Power supply Simple unit cabling Up to 3 repeaters per control panel Same modern enclosure as control panels Repeater panel not out of place in public areas
    Details
  • Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
    Details
  • Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
    Details
  • Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
    Details
  • Key Features:; Zonal relay card as standard One-man test facility Non-latching zone feature Class change input Fire and fault relays Discreet enclosure; Stylish and compact panel with 6 touch button keypad control of all functions and LED indication Simple one-shot weekly test with auto-reset facility Comprehensive power, fire, and fault LED indicators and integral piezo buzzer for on-board fire or fault indication Battery high/low voltage alarm facility Log book storage facility in front panel
    Details
  • 2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard No batteries included; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
    Details
  • 2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Batteries not included; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
    Details
  • Cooper FX2208CFCPD Conventional 8 Zone Control Panel; 2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
    Details
  • Facility for signalling to repeater panel provided as standard on 8 zone panel Surface or semi-flush mounting Displays essential information at other key locations in a large building/site Displays zone fire and fault conditions; Repeater matches the style and appearance of the control panel Requires only a single pair of wires to receive signals from control panel reducing cost of installation
    Details
  • Fike Ocelus Conventional 2 Zone Fire Panel – 500-0002; Access via password – removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies
    Details