  • 1. Remove the transparent cover using the corner stud key. 2. Lift out the foam filter element from the filter tube using tweezers or long nosed pliers. 3. Fit a new filter element. Ensure that the filter is not compressed during fitting and that it is positioned flush with the top of the filter tube. 4. Replace the transparent cover.
    Details
  • 1. Remove the transparent cover using the corner stud key. 2. Lift out the foam filter element from the filter tube using tweezers or long nosed pliers. 3. Fit a new filter element. Ensure that the filter is not compressed during fitting and that it is positioned flush with the top of the filter tube. 4. Replace the transparent cover.
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) Suitable for use in Zone 0,1 & 2 Robust GRP Body Suitable for offshore and petrochem Certificated Intrinsically Safe; Certification: CENELEC EN50014, 20 & 39 BAS02ATEX1258X EExia IIB T4 Zones 0,1 & 2 Material: UV stable glass reinforced polyester body. Clear polycarbonate cover/lens. Retained stainless steel cover screws. Finish: Painted Red Tube Type: Xenon discharge Lens Colour: Clear Terminals: 8 x 2.5mm2 Flash Rate: 1 flash per second Cable Entries: Up to 3 x M20 via knockouts Tube Energy: 0.5 Joules Weight: 1.4kg Certified Temperature: -55°C to + 60°C Ingress Protection: IP66 & IP67 Tube Life: >1 x 106 Flashes Voltage: 24V via suitable barrier Current Consumption: 71mA max nominal
    Details
  • Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Robust Corrosion Resistant GRP body High Power (5 Joule) Certificated Flameproof; Voltage: 24Vdc Tube Energy: 5 Joules Peak Current Consumption (mA): 320 Effective Intensity (Cd): 29 Peak Intensity (Cd): 22213 Power Consumption (Watts): 8 Note: The Cd figures are for a clear lens @ 1Hz flash rate. For red lens multiple by 0.15 Weight: 2.5Kg Certified Temperature: EExd -55°C to + 70°C (T4) -55°C to + 55°C (T5) -55°C to + 40°C (T6) Ingress Protection: IP66 & IP67 Terminals: 6 x 2.5mm2 Entries: 2 x 20mm ISO EExd. Certification: BASEEFA EExd IIB 135°C (-55 to AMB +70°C)T4 100°C (-55 to AMB + 55°C)T5 85°C (-55 to AMB + 40°C)T6 Cert. No. 99 ATEX 2195X. CENELEC EN50014 and EN50018 Material Body: Glass reinforced polyester Lens: Glass Cover Screws + Backstrap: Stainless steel 316 Finish: Red
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Allows the 801/802/812/901 & 912 Sounder Base to become Addressable without the need to fit a Detector, thus creating an Addressable Loop Powered Sounder Suitable for wall or ceiling mounting Sounder Selection Tones as per 801/802/812/901 & 912 Sounder Base Fits the 801RB Relay Base to provide an Addressable Relay Base without the need to fit a Detector Colour matched to Sounder Bases Locked into Sounder Base using Detector Locking Pin SAM 800 is configurable in CONSYS SAB800 / SAB801 may be used with 5B or MUB bases SAB800 / SAB801 adds a Flashing Red Beacon facility to the 801/802/812/901 & 912 Sounder Base SAB801 Low current consumption (loop powered) SAB800 has two Modes of Operation - continuous or 2Hz flash, configurable in CONSYS SAB801 has two Modes of Operation - continuous or 1Hz flash , configurable in CONSYS
    Details
  • Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details
  • Key Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
    Details