- CE label according to DIN EN 14604, ROHS, German TÜV.
- Made In Germany
- 12 years of battery life (lithium).
- Bi-sensor processor technology (smoke + heat).
- Certified magnetic carrier system with special adhesive gel pad.
- Maximum false alarm protection.
- Kitchen suitable (Condensation Barriers).
- Insect Shield.
- Alarm signal > 85 dB.
- 60 m² detection range
- Large, easy to use testing/stop button (78 cm²)
- No battery change necessary
- Processor technology / intelligent software analysis of sensor readings
- Cyclical genuine self-test function
- Help signal (e.g. low battery status or contamination)
-
The PX-1 is a stand-alone smoke alarm complying with EN 14604, equipped with a built-in long-term lithium battery. Our devices therefore do not require annoying and expensive battery changes. This represents just one of the many ways how we actively contribute to the protection of our environment. -
One Minute Auto-Alignment – The Fireray One’s one-minute auto-alignment feature not only saves time during installation, the quality of alignment is also guaranteed by the automation protocol. Using the Fireray One, a high level of protection is always achieved. One standalone product – The Fireray One is a standalone reflective beam detector that requires no specialist tools or prior knowledge or training to get it up and working. One personal installation – All of the internal and external features of the Fireray One ensure that anyone can align the beam detector perfectly, because the experience and expert knowledge of beam detection has been engineered into the product! Movement Tracker – The Fireray One contains Building Movement Tracking that maintains its own alignment once installed. Its optics are fully enclosed in an IP-rated casing with a flat surface for easy cleaning without affecting alignment. An integrated user-interface at the front of the product allows realignment and programming without having to dismount the detector. -
-
-
-
Highest immunity to false sources Solar blind Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Generators Compressor Stations High Voltage Equipment Power Plants Fuel Loading Racks Chemical Plants Tunnels uclear Power Sites Storage Tanks Engine Rooms Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Petrochemical Offshore/Onshore LNG/LPG Production; Worldwide approvals include EN54:10, with VdS and LPCB certification, as well as SIL 2 rated.; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Wiring Diagram Talentum UV / IR2 - One detector for every application Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect? -
Highest immunity to false sources Solar blind High ambient temperature applications Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Generators Compressor Stations High Voltage Equipment Power Plants Fuel Loading Racks Chemical Plants Tunnels Nuclear Power Sites Storage Tanks Engine Rooms Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Petrochemical Offshore/Onshore LNG/LPG Production; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Wiring Diagram Distance Sensitivity of the Talentum Flame Detector Talentum UV / IR2 - One detector for every application What flame detector should I choose? What type of flames can your Talentum detect? -
Highest immunity to false sources Increased environmental protection Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22 SIL 2 rated.; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - One detector for every application What flame detector should I choose? What type of flames can your Talentum detect? Distance Sensitivity of the Talentum Flame Detectors -
Highest immunity to false sources Solar blind High ambient temperature applications Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect? -
Highest immunity to false sources Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel loading racks Storage tanks Aircraft hangers Petrochemical onshore/offshore Biomass storage and handling LNG/LPG production; ATEX: II 2GD Ex d IIC T6 [Zones 1, 21, 2 and 22] Worldwide approvals include EN54:10, with VdS and LPCB; Talentum UV / IR2 - User Manual Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - Maintenance Guide Talentum UV / IR - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose What types of flames can Talentum detect? -
Key Features:; Highest immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Aircraft hangars Engine rooms Engine test facilities Generators High voltage equipment Nuclear industry Power plants Storage tanks; Flame Detector - Maintenance Guide Flame Detector - User Manual Flame Detector - Wiring Diagram Flame Detector - Installation Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect? -
Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangers Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Talentum One Detector for Every Application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What types of flames can Talentum detect?