/C-Tec
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP55C rated (weatherproof). Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP21C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP33C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP55C rated (weatherproof). Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders). Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA. Alarm Current at 18Vdc = 3.8mA. IP21C rated. Manufactured in the UK by C-TEC.
    Details
  • LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD. Impressive 100dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) IP33C rated. Manufactured in the UK by C-TEC.
    Details
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'C-3-8.5' light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area). Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders). Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Alarm Current at 30Vdc = 5.5mA Alarm Current at 18Vdc = 3.8mA Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'O-R-3-2.5-17' light distribution. Ideally suited for use in corridors and other rectangular areas. Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • Key Features; For use with ceiling mounted ActiV or CAST devices on retrofit installations. Helps cover the decorating marks left by older Grade D domestic type systems. Includes multiple mounting holes and large cable entry section.; Compatibility - Compatible with C-TEC's ceiling mounted ActiV and CAST range of fire alarm devices. Construction & finish - Durable white polycarbonate, Width - 152mm diameter.
    Details