/C-Tec
  • Key Features:; Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors Easy to fit with lots of working space Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors Integrated detector/base locking mechanism, head removal tool and ID tag Simple ‘click and twist’ design Remote LED terminals for the optional connection to a BF318 Remote indicator Bright tin plated steel terminals can accept fire rated cable of up to 2.5mm in diameter C4408D diode and C4408 non-diode bases available* Compatible with C-TEC’s entire range of ActiV conventional smoke and heat detectors
    Details
  • Activation current – Typically 30mA @ 24VDC Indicators – Red relay activated LED Connections – +V; -V (Supply); NC; C; NO (SW1 & SW2). Contact rating @ 24Vdc is 5A (resistive) 2A (inductive); Contact rating@ 240Vac is 5A (resistive) 2A (inductive) Product dimensions (mm) – 85w x 85h x 27d (mm) can be mounted onto a standard UK 25mm single gang flush or surface back box Construction & finish – White PVC plate; light grey label; silver nickel contacts IP Rating – IP40 Weight – 78g Operating temperature – -10C to +60C
    Details
  • C-Tec BF360-12 Boxed EN54 12v 2a Power Supply Unit (VDS Certified); Max. physical battery size (with STU plate): 1 x 12V 3 Ah Max. physical battery size (no STU plate): 1 x 12V 7 Ah Standard battery charging capacity: 2 Ah to 12 Ah Output option A: 1.8A DC current, 0.2A charge current Output option B: 1.3A DC current, 0.7A charge current Enclosure size (WxHxD): 380 x 235 x 96mm Physical attributes: Plastic lid and base
    Details
  • C-Tec BF360-24 Boxed EN54 24v 1.5a Power Supply Unit (VDS Certified); Low current consumption. Deep discharge battery protection and EN54 compliant flagging of battery impedance faults. Single-pole volt-free changeover relay that switches for any fault condition. Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment). Link selectable battery charging capacity. Optional high-temperature output activates when internal box temperature reaches 55°C, for connection to ventilation fans.
    Details
  • C-Tec 24v 1.5A EN54-4/A2 Boxed Power Supply Unit (VDS Certified); BF362-1; Low current consumption Deep discharge battery protection and EN54 compliant reporting of battery impedance faults Single-pole volt-free changeover relay that switches for any fault condition Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment) Link selectable battery charging capacity Environmentally-friendly charging circuit - dissipates just 0.35W compared to the industry norm of around 2.55W. Optional high-temperature output activates when internal box temperature reaches 55oC, for connection to ventilation fans, etc. Optional handheld status reader (shows internal temperature, charging voltage and current of connected PSU). Serial data link also provided for third-party OEM equipment All boxed versions third-party certified to EN54-4 (1997/A2:2006) by the VdS or LPCB
    Details
  • C-Tec 24v 3A EN54-4/A2 Boxed Power Supply Unit (LPCB Certified) BF362-3; Low current consumption Deep discharge battery protection and EN54 compliant reporting of battery impedance faults Single-pole volt-free changeover relay that switches for any fault condition Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment) Link selectable battery charging capacity Environmentally-friendly charging circuit - dissipates just 0.35W compared to the industry norm of around 2.55W. Optional high-temperature output activates when internal box temperature reaches 55oC, for connection to ventilation fans, etc. Optional handheld status reader (shows internal temperature, charging voltage and current of connected PSU). Serial data link also provided for third-party OEM equipment All boxed versions third-party certified to EN54-4 (1997/A2:2006) by the VdS or LPCB
    Details
  • C-Tec 24v 5A EN54-4/A2 Boxed Power Supply Unit (VDS Certified); BF362-5; Low current consumption Deep discharge battery protection and EN54 compliant reporting of battery impedance faults Single-pole volt-free changeover relay that switches for any fault condition Three LED indicators - supply present, general fault and auxiliary fault (for optional connection to third-party equipment) Link selectable battery charging capacity Environmentally-friendly charging circuit - dissipates just 0.35W compared to the industry norm of around 2.55W. Optional high-temperature output activates when internal box temperature reaches 55oC, for connection to ventilation fans, etc. Optional handheld status reader (shows internal temperature, charging voltage and current of connected PSU). Serial data link also provided for third-party OEM equipment All boxed versions third-party certified to EN54-4 (1997/A2:2006) by the VdS or LPCB
    Details
  • Key Features:; Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM
    Details
  • Key Features:; Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote). PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal. Aux. fire relay is active in an alarm condition provided all relevant delays have expired. Remote relay is active during any Alarm Condition provided all relevant delays have expired. Outputs are NOT designed to switch mains voltages.
    Details
  • Key Features:; Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote) and eight output per zone relays. PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal. Aux. fire relay is active in an alarm condition provided all relevant delays have expired. Remote relay is active during any Alarm Condition provided all relevant delays have expired. Output per zone relays will changeover when the corresponding zone is in alarm (subject to certain conditions - for full details refer to the instructions, downloadable below). Outputs are NOT designed to switch mains voltages.
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction
    Details
  • Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Approved to EN54:12 and UL268
    Details
  • Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Programmable Sensitivity and Fire Thresholds 20mm Cable Gland Knockouts on System Controller 2-wire interface from System Controller to Detector
    Details