/C-Tec
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'C-3-8.5' light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area). Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • Key Features:; Includes three selectable voice message pairs. Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area) using the same lenses and electronics as our EN54-23, 3 & 17 certified base sounder VAD. Onboard short-circuit loop isolator. 550µA quiescent current. 19.5mA alarm current @24V DC (VAD lit, voice sounder on max). Group addressing facility allows multiple devices to be operated simultaneously. 7 selectable volume levels. Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. IP21C rated. Detector spur wires included.
    Details
  • Key Features:; Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. IP21C rated.
    Details
  • Key Features:; Third-party certified to EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'W-3-3.1' light distribution when wall mounted (min. 0.4 lux over a 2.4 x 3.5m cuboid area). Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. IP21C rated.
    Details
  • Key Features:; Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area). Supplied with a BF431QCP quick connect plate and detector spur wires. Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. IP21C rated.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF560-12/E Caged & BF560-12/C PCB-only versions available.
    Details
  • Key Features:; Metal base plate facilitates straightforward mounting inside third-party OEM enclosures. Includes a single-pole voltfree changeover relay that switches for any fault condition. Includes a fault type & hazardous voltages present LED. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF560-24/E caged & BF560-24/C PCB-only versions available.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF562-1/E caged & BF562-1/C PCB-only versions available.
    Details
  • Key Features:; Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details