UV spectrum design Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours 5-Year Warranty User Programmable via HART or RS-485; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Crowcon 40/40U - Data Sheet
-
Multi Spectrum Design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity Selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static Fuel Cell systems; Crowcon 40/40M - Data Sheet
-
Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Crowcon 40/40R - Data Sheet
-
Triple Spectrum Design - for long distance detection and high false alarm immunity Sensitivity Selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Crowcon 40/40I - Data Sheet
-
UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Crowcon 40/40L - Data Sheet
-
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
-
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
-
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
-
UV/IR Dual-Sensor High-Speed Response 50m sec Response to Saturated Signal Large Field of View (100° horizontal/vertical) User Programmable Functions Configurable via software from a PC or handheld device Immune to False Alarms (solar blind); Aerospace Industry - Hydroxy fuels, Hydrogen and Hydrazine fuels Aircraft Hangars - landing gear pits, under-wing and over-wing protection Automotive - manufacturing, paint spray booths Chemical Industry - production, storage, transportation Paint - manufacturing facilities Petrochemicals - production, storage, shipping facilities Pharmaceutical Industry Polymers and Glue - manufacturing and curing Power Generation Facilities - pump areas, generator rooms, unmanned stations, gas-fired and coal-fired reactors Printing Industry - solvent handling, presses, drying processes Warehouses - storage facilities for flammable materials; Crowcon 20/20ML - Data Sheet Crowcon 20/20ML - User Manual
-
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
IR Features: No poisoning effects Long life sensor and no burnout % vol. measurement for purging applications % LEL measurement in air or inert backgrounds Single or dual range measurement IR CO2 detection 0-5%
-
IR Features: No poisoning effects Long life sensor and no burnout % vol. measurement for purging applications % LEL measurement in air or inert backgrounds Single or dual range measurement IR CO2 detection 0-5%
-
Key Features: Loud 85dB at 1m Vivid LED alarms with top visibility Confidence blip, low battery and TWA warnings Timed data logging with 100-hour capacity Wide range of electrochemical oxygen and toxic gas sensors Interchangeable sensor modules Comprehensive data logging with sire and user names Triax casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment Full buoyancy Simple windows software interface QuickCal rapid calibration
-
Key Features: Loud 85dB at 1m Vivid LED alarms with top visibility Confidence blip, low battery and TWA warnings Timed data logging with 100-hour capacity Wide range of electrochemical oxygen and toxic gas sensors Interchangeable sensor modules Comprehensive data logging with sire and user names Triax casing will not crack or shatter when dropped Unique internal design will resist the harshest treatment Full buoyancy Simple windows software interface QuickCal rapid calibration
-
Key Features: Tough polycarbonate housing Water and dust resistant to IP65 Full over moulding 2 levels of instantaneous alarm and TWA alarms for toxic versions 95dB audible warning Vivid twin red/blue visual alarm Internal vibrating alarm Versions available for flammable gas, oxygen and toxic gases Rechargeable versions for all gas types - please use the C011318 CHARGER. Non-rechargeable versions for all gas types Real time TWA and peak display options Fully interchangeable intelligent sensor modules One button operation Backlit display for gas diagnostics and operating status
-
Key Features: Detects at up to 30ms distant - keeps operators out of harms way Detects at up to 100m with reflector - hard-to-reach areas at height or behind barriers can be monitored Green guide laser light - clear visibility of survey point, even in bright sun light Point and shoot technology - required little or no training and is easy to use Compact and lightweight - truly portable, can fit in a pocket Green guide laser light - clear visibility of where you are surveying even under strong sunlight Wide OLED display - clear and bright readout on screen No moving parts - little maintenance required Self-check and automatic calibration on start-up - ensures accurate and reliable readings; removes the need to return for regular calibration