UV spectrum design Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours 5-Year Warranty User Programmable via HART or RS-485; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Crowcon 40/40U - Data Sheet
-
Multi Spectrum Design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity Selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static Fuel Cell systems; Crowcon 40/40M - Data Sheet
-
Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Crowcon 40/40R - Data Sheet
-
Triple Spectrum Design - for long distance detection and high false alarm immunity Sensitivity Selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Crowcon 40/40I - Data Sheet
-
UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility High Reliability - MTBF - minimum 150,000 hours; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Crowcon 40/40L - Data Sheet
-
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
-
Long distance Flame Detection (up to 140ft / 43m) Large Field of View (100° horizontal / 90° vertical) Highest immunity to false alarms RS-485 Modbus Compatible Automatic and Manual Built-In-Test (BIT) 3 Year Warranty; Airport Terminals Train Stations and Terminals Storage Areas Archives Shopping Malls Hospitals Car Parking Towers and Garages Public Buildings Banks and Offices Historical and Cultural Sites Aircraft Hangers Cable Tunnels; Crowcon 20/20MPI - Data Sheet Crowcon 20/20MPI - User Manual
-
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
-
UV/IR Dual-Sensor High-Speed Response 50m sec Response to Saturated Signal Large Field of View (100° horizontal/vertical) User Programmable Functions Configurable via software from a PC or handheld device Immune to False Alarms (solar blind); Aerospace Industry - Hydroxy fuels, Hydrogen and Hydrazine fuels Aircraft Hangars - landing gear pits, under-wing and over-wing protection Automotive - manufacturing, paint spray booths Chemical Industry - production, storage, transportation Paint - manufacturing facilities Petrochemicals - production, storage, shipping facilities Pharmaceutical Industry Polymers and Glue - manufacturing and curing Power Generation Facilities - pump areas, generator rooms, unmanned stations, gas-fired and coal-fired reactors Printing Industry - solvent handling, presses, drying processes Warehouses - storage facilities for flammable materials; Crowcon 20/20ML - Data Sheet Crowcon 20/20ML - User Manual
-
Triple Spectrum Design 80% Less Power Consumption Highly Immune to False Alarms Large Field of View (100° horizontal/vertical) Sensitivity Selection User-Programmable Functions Configurable via software from a PC or handheld device Automatic and Manual Built-In-Test (BIT) Standard 4-Wire Connection 4-20mA sink or source (3-4 wires) configuration RS-485 Modbus Compatible MTBF Minimum 100,000 Hours 3-Year Warranty FM Approval (Functional) EN54-10 (VdS) Approved for 20/20MI-1; Aircraft-hangars and maintenance areas including landing gear pits Automotive parts manufacturing Car parking towers and garages Chemical industry Mining and heavy-duty vehicles Nuclear power plants Paint spray booths Petrochemical facilities Power generation - pumps, generators, and unmanned stations Printing-presses and facilities Recreational and sports arenas (facilities) Storage areas Tank farms with fixed or floating roofs Wet bench manufacturing; Crowcon 20/20MI - Data Sheet Crowcon 20/20MI - User Manual
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure
-
Key Features: NDIR (Non-Dispersive Infrared) sensor Measures up to 50,000ppm Up to 3 Remote Display units Quick & easy installation LCD readout for CO2 and Temperature levels Relay output to control a fan to ventilate confined spaces Audible and Visual alarm indications IP54 enclosure