/Elmdene
  • Key Features:; 1.2mm Powder coated Steel Red with white Fire logo 2 Keys Provided (keyed alike)
    Details
  • Powder coated Steel Red with white Fire logo 2 Keys Provided 5 Years Warranty
    Details
  • Removal of an external 24V dc supply (BS 7273 Compliant) Opening of a normally closed volt-free contact Closing of a normally open volt-free contact; Efficient switch mode operation Wide input voltage range Remote control of output Choice of control options LED indication (within enclosure) Mains transient protection Fail safe operation Screen printing available 3 year warranty
    Details
  • Removal of an external 24V dc supply (BS 7273 Compliant) Opening of a normally closed volt-free contact Closing of a normally open volt-free contact; Remote control of output Choice of control options LED indication Mains transient protection Fail safe operation 3 year warranty
    Details
  • Universal mains input voltage 90-264vac Additional 0.5A to charge 2 x 12V standby batteries High efficiency electronics for reduced running costs and lower operating temperatures Continuous full rated current to load Modular construction for ease of maintenance & installation Installer safe design with all high voltage electronics fully shrouded Reverse battery connection protection Full electronic short circuit and overload protection on load output Mains transient protection circuit Green Mains present LED Yellow Fault LED
    Details
  • Universal mains input voltage 90-264vac Additional 0.5A to charge 2 x 12V standby batteries High efficiency electronics for reduced running costs and lower operating temperatures Continuous full rated current to load Modular construction for ease of maintenance & installation Installer safe design with all high voltage electronics fully shrouded Reverse battery connection protection Full electronic short circuit and overload protection on load output Mains transient protection circuit Green Mains present LED Yellow Fault LED
    Details
  • Universal mains input voltage 90-264vac Additional 0.5A to charge 2 x 12V standby batteries High efficiency electronics for reduced running costs and lower operating temperatures Continuous full rated current to load Modular construction for ease of maintenance & installation Installer safe design with all high voltage electronics fully shrouded Reverse battery connection protection Full electronic short circuit and overload protection on load output Mains transient protection circuit Green Mains present LED Yellow Fault LED
    Details
  • 27.6V dc output Cost effective switch mode technology High energy efficient - reducing energy bills Modular construction means easy maintenance and upgrading Full rated current to load +0.8A battery charging 90 to 264V ac range Deep discharge protection Electronic overload protection 3 year warranty Fits batteries up to 2 x 38Ah 'H' Box Power Supply - 410h x 390w x 90d (mm) Clam Lid Mains transient protection LED indication:
    Details
  • 27.6V dc output Cost effective switch mode technology High energy efficient - reducing energy bills Modular construction means easy maintenance and upgrading Full rated current to load +0.8A battery charging 90 to 264V ac range Deep discharge protection Electronic overload protection 3 year warranty Fits batteries up to 2 x 38Ah 'R' Box Power Supply - 410h x 390w x 90d (mm) Clam Lid Mains transient protection LED indication:
    Details
  • 27.6V dc output Cost effective switch mode technology High energy efficient - reducing energy bills Modular construction means easy maintenance and upgrading Full rated current to load +0.8A battery charging 90 to 264V ac range Deep discharge protection Electronic overload protection 3 year warranty Mains transient protection Fits batteries up to 2 x 17Ah 'R' Box Power Supply - 410h x 390w x 90d (mm) Clam Lid LED indication:
    Details
  • Advantages of Switch Mode:; 27.6V dc output Cost effective switch mode technology High energy efficient - reducing energy bills Modular construction means easy maintenance and upgrading Full rated current to load +0.8A battery charging 90 to 264V ac range Deep discharge protection Electronic overload protection 3 year warranty Mains transient protection Fits batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid LED indication:
    Details
  • 27.6V dc output Cost effective switch mode technology High energy efficient - reducing energy bills Modular construction means easy maintenance and upgrading Full rated current to load +0.8A battery charging 90 to 264V ac range Deep discharge protection Electronic overload protection 3 year warranty Mains transient protection Fits batteries up to 2 x 1.2Ah 'A' Box Power Supply - 200h x 230w x 80d Hinged Lid LED indication:
    Details
  • Key Features:; 465w x 534h x 270d (mm) When used with 2 x 65Ah batteries & STX2410-E the load changes to 7.2a and battery charging to 2.6a
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 10 A current to load at 27.6V dc nominal regulated output. Charging capability to support 18, 38 or 65Ah batteries with intelligent load enhancement. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls to 21 V. Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present. RS232 serial interface for fault reporting and diagnostics interface to OEM equipment. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid Can use BATT-BOX-65 to make product 7.2a load + 2.6a battery charging with 2 x 65Ah Batteries
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 10 A current to load at 27.6V dc nominal regulated output. Charging capability to support 18, 38 or 65Ah batteries with intelligent load enhancement. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls to 21 V. Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present. RS232 serial interface for fault reporting and diagnostics interface to OEM equipment. Suitable to fit batteries up to 2 x 38Ah 'H' Box Power Supply - 420h x 420w x 180d Hinged Lid
    Details
  • Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 5A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 38Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 2A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply: 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1 +A2. Up to 1.2A current to load at 27.6V dc nominal regulated output. Charging capability to support 1.2 to 7Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit impedance (Ri) in excess of 500mW, caused by connector or wiring problem/corrosion, within 4 hours. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 1.2Ah 'T' Box Power Supply - 300h x 240w x 63d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1 +A2. Up to 1.2A current to load at 27.6V dc nominal regulated output. Charging capability to support 1.2 to 7Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit impedance (Ri) in excess of 500mW, caused by connector or wiring problem/corrosion, within 4 hours. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details