  • Up to 250 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level at point in alarm Viewing 3000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes
    Details
  • 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation
    Details
  • 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation
    Details
  • 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions available (1.5 A or 2.5 A power supply) Up to 128 Addresses / 32 Zones Easy to programme Auto Addressing Auto mapping with Intelli-Zone feature Out of the Box On Line Help function USB interface dual role Host/Device Multi Users/Multi Installers (Up to 2 Installers, 8 Users) Walk test function 4000 Event Log Loop break location On board PSTN communicator Optional IP board GSM/GPRS as external module LCD display (160 Characters) Up to 4 repeaters Up to 4 Multifunction interfaces for printer / simplified fire brigade panels Event transmission via PSTN and IP Front panel controls enabling text and configuration changes Displays temperature, CO level and smoke level at any point Automatic drift compensation
    Details
  • 3 in 1 loops Up to 800mA current dynamically shared across 3 loop circuits Auto mapping with Intelli-Zone feature Online Help function USB interface dual role Host/Device Multi users and multi installers (Up to 2 installers, 8 users) Walk test function 4000 Event Log Loop break location On board PSTN communicator GSM/GPRS as external module Up to 8 repeaters and up to 7 FC500 Series panel clients Event transmission through PSTN and IP Automatic drift compensation Fast and simple system configuration, also offline Transferable user database Device graphic displayed Battery and wiring calculation Customizable cables database Visualization of all the devices assigned to a single zone Remote real time visualization of control panel loop and zone status, and so on. Easy remote user interface with control buttons (reset, silence, evacuate) Multilevel map based on a tree structure Access device data from any pages of the map Configuration downloadable to USB memory stick Capability to print zone label sheet for front panel customization?
    Details
  • 6 in 2 loops Up to 800mA current dynamically shared across 3 loop circuits Auto mapping with Intelli-Zone feature Online Help function USB interface dual role Host/Device Multi users and multi installers (Up to 2 installers, 8 users) Walk test function 4000 Event Log Loop break location On board PSTN communicator GSM/GPRS as external module Up to 8 repeaters and up to 7 FC500 Series panel clients Event transmission through PSTN and IP Automatic drift compensation Fast and simple system configuration, also offline Transferable user database Device graphic displayed Battery and wiring calculation Customizable cables database Visualization of all the devices assigned to a single zone Remote real time visualization of control panel loop and zone status, and so on. Easy remote user interface with control buttons (reset, silence, evacuate) Multilevel map based on a tree structure Access device data from any pages of the map Configuration downloadable to USB memory stick Capability to print zone label sheet for front panel customization
    Details
  • 1000 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level of each detector 3000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes Up to 24 panels networkable Up to 7 fully functional repeaters available
    Details
  • Key Features:; 1000 addresses available on panel 640 Character Display Permanently displays system status Displays temperature, CO level and smoke level of each detector 10,000 event log Manual and Automatic walk test and reporting functions Automatic battery test Detector service functions Front panel controls enabling text and configuration changes Up to 99 panels networkable Up to 7 fully functional repeaters available
    Details
  • 8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Compact shallow housing or deep housing - designed for standard or extended battery standby period?
    Details
  • 8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Compact shallow housing or deep housing - designed for standard or extended battery standby period?
    Details
  • 8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Integral slot card cage – easily expanded with a number of slot card options?
    Details
  • 8.4” TFT colour touch screen multilingual user interface -architecturally attractive and fully programmable Ergonomic Icon Display - simple to operate user interface eliminates operator errors Touch sensitive status LEDs provide event summary information - instant access to detailed event information Context sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent users User configurable on screen site maps - no need for additional site plans Programmable graphic quiescent display - opportunity for customer branding Comprehensive point management and disable functions - gives the user full control and reduces service and maintenance effort Selectively view or print from the extensive 10,000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigations Keyless log-on using RFID tags – identifies and logs user actions Flexible single or dual hardware loop configurations - optimise loop power and address capacity Integral slot card cage – easily expanded with a number of slot card options?
    Details
  • Up to 250 detectors per loop Protective optical chamber screen Robust coated electronics Extended service life Fire, isolate and fault LED indications
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Multiple fire detection modes FireClass digital detection algorithms CO fire detection technology Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Integral LED indicator for easy identification of operation Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Hazardous area models available IP67 Waterproof models for external applications
    Details
  • Integral Short Circuit Isolator Dual Colour LED Indication EN54-11 Certification Compact, Modern Styling Test Key for Fast Testing IP67 Ingress Protection models for external applications
    Details
  • Integral LED indicator for easy identification of operation Surface or Flush Mounting Test key facility, speeds maintenance visits Optional transparent hinged cover Hazardous area models available IP67 Waterproof models for external applications
    Details
  • Integral short circuit isolator. Dual colour LED indication. EN54-11 certification. Compact, modern styling. Test key for fast testing. IP67 ingress protection models for external applications.
    Details
  • Loop powered-reduced installation costs High sound output characteristics Low current consumption Clean lines, modern styling Easy to install, low installation costs Weatherproof units for outdoor use Multiple tones and flash rate to suit individual requirements Integral line isolator
    Details
  • Loop powered-reduced installation costs High sound output characteristics Low current consumption Clean lines, modern styling Easy to install, low installation costs Weatherproof units for outdoor use Multiple tones and flash rate to suit individual requirements Integral line isolator
    Details
  • Key Features:; Loop powered-reduced installation costs High sound output characteristics Low current consumption Clean lines, modern styling Easy to install, low installation costs Weatherproof units for outdoor use Multiple tones and flash rate to suit individual requirements Integral line isolator
    Details
  • Key Features:; Loop powered-reduced installation costs High sound output characteristics Low current consumption Clean lines, modern styling Easy to install, low installation costs Weatherproof units for outdoor use Multiple tones and flash rate to suit individual requirements Integral line isolator
    Details
  • Key Features:; High output programmable sounder base and sounder beacon base Aesthetically discreet Superior performance and reliability Designed for rapid installation with a Snap-Fit feature Remote LED connection Software programmable 15 Tones and 2 Flash Rates Audible alarm approved to EN54-3
    Details
  • Key Features:; Optional conduit entry backboxes Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection Optional short circuit isolator in each base Loop powered sounder bases
    Details
  • Key Features:; Optional conduit entry backboxes Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection Optional short circuit isolator in each base Loop powered sounder bases
    Details
  • A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic Conventional Bell Tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector
    Details
  • Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • A compact and discrete solution VAD approved to EN54-23 with two ranges, standard power and high power available High Power option provides a larger VAD coverage volume compared to Standard Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Self-test Shorter Light Pulse for faster response Optimise the system design for lowest power requirements and lowest cost installation Triple light source One point of installation for detector, sounder and visual indicator with no additional wiring Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar. Realistic Conventional Bell Tone 2 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VADs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Provides an EN54-23 approved upgrade path for legacy systems
    Details