-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Key Features:; 12 zonal fire and fault indications Activate controls via keyswitch or code entry 1.25 Amp switch mode power supply Nom 27V DC Class change I/P Alert I/P 6 programmable switched -ve outputs Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays
-
Haes White Fire Alarm Mains Isolator Switch MISW-W; Secure isolation for fire alarm mains supply voltage Both neutral & live is switched Protection fuse provided Compliant with BS 5839 Pt1:2013 Red or white box Surface or flush fitting Power indicator LED
-
Haes Red Fire Alarm Mains Isolator Switch MISW-R; Secure isolation for fire alarm mains supply voltage Both neutral & live is switched Protection fuse provided Compliant with BS 5839 Pt1:2013 Red or white box Surface or flush fitting Power indicator LED
-
Key Features:; 8 amp relay Suitable for mains switching Suppressed and polarised relay 24v coil Red or white box Surface or flush fitting LED ‘isolated’ indication (yellow) Double pole relay Isolate key switch Selectable internal buzzer on isolation Option switch to energise relay on isolation
-
Key Features:; 8 amp relay Suitable for mains switching Suppressed and polarised relay 24v coil Red or white box Surface or flush fitting LED ‘isolated’ indication (yellow) Double pole relay Isolate key switch Selectable internal buzzer on isolation Option switch to energise relay on isolation
-
Key Features:; 8A double pole volt free changeover relay Contacts rated at up to 250vac 24vdc coils, polarised and suppressed ‘Activated’ LED indicator Nylon self-adhesive mounting pillars; All relays polarised and suppressed 24v coils Self-adhesive mounting pillars Relay activated LED indication Fused and un-fused versions
-
Coils are polarised and suppressed Fused and un-fused versions available 8 amp relays suitable for switching mains
-
Key Features:; 8 amp double pole relay Suitable for mains switching Individually fused outputs on fused version Red LED to indicate relay activated
-
Coils are polarised and suppressed Fused and un-fused versions available 8 amp relays suitable for switching mains
-
Key Features:; 8 amp double pole relay Suitable for mains switching Individually fused outputs on fused version Red LED to indicate relay activated
-
-
-
Key Features:; High efficiency switched mode power supplies Compact 1A and 2.5A versions Regulated 24vdc supply 3 year warranty as standard Integral load switching relay Supply ‘on’ indication Continuously rated at design load (see over) Mains input range 88-264vac Overload protected
-
Key Features:; High efficiency switched mode power supplies Compact 1A and 2.5A versions Regulated 24vdc supply 3 year warranty as standard Integral load switching relay Supply ‘on’ indication Continuously rated at design load (see over) Mains input range 88-264vac Overload protected
-
Key Features:; High efficiency switched mode power supply Mini enclosure Regulated 24vdc supply 3 year warranty as standard Integral load switching relay Supply ‘on’ indication Continuously rated at 0.7A Mains input range 100-245vac Overload protected
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.
-
Key Features:; High efficiency switched mode power supplies Compact 1.5A, 3.0A and 5.0A versions Fully compliant to EN54-4 Power and fault indication 3 year warranty as standard A range of power supply equipment with power output options to suit most applications. Wide AC input range on the 3.0A and 5.0A versions All models monitor the battery internal series resistance.