/Haes
  • Key Features:; 8 amp double pole relay Suitable for mains switching Boxed unit or PCB only 0-255 second, minute or hour timer Delay timer or pulsing relay
    Details
  • Key Features:; 8 amp double pole relay Suitable for mains switching Boxed unit or PCB only 0-255 second, minute or hour timer Delay timer or pulsing relay
    Details
  • 2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
    Details
  • 2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
    Details
  • Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
    Details
  • Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
    Details
  • Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
    Details
  • Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
    Details
  • Key Features:; 12 zonal fire and fault indications Activate controls via keyswitch or code entry 1.25 Amp switch mode power supply Nom 27V DC Class change I/P Alert I/P 6 programmable switched -ve outputs Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays
    Details