Continually corrects itself against building movement Controlled and adjusted from ground level utilising included controller 5 to 40 m standard detection range Extensions kits available to enhance detection range up to 100 m Fully compatible with the Hochiki ESP analogue addressable protocol -
Ultra-small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Single sampling pipe up to 50 m in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications -
Ultra-small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Two sampling pipes up to 100 m (aggregate) in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications -
Volt-free Fire-1 and Fault relay outputs are provided for remote monitoring by local fire detection or BMS systems High sensitivity provided by laser based forward light scatter for reliable early warning Four sampling pipes up to 200m (aggregate) in length (still air) False alarms reduced by unique laser sensing technology - able to discriminate against dust RS485 communications built in as standard for networking and remote communications -
High sensitivity provided by laser based forward light scatter for reliable early warning Four sampling pipes up to 200 m (aggregate) in length (still air) False alarms reduced by unique dust discrimination RS485 communications for networking and remote communications Command Module allows control over other FIRElink units on network -
Key Features; Low Profile Low Current Consumption Fully Supressed and Polarised 100 dB (A) At 1 meter Simple Installation with Multi Fixing Base Plate Weatherproof -
Key Features; Low Profile Low Current Consumption Fully Supressed and Polarised 95 dB (A) at 1 meter Simple Installation with Multi Fixing Base Plate -
User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin fire LED's allow 360° viewing Pulsing/non-pulsing controlled from panel*1 Electronically Addressed Approved by LPCB, LR & GL -
-
-
Fast response Integral short-circuit isolator Bi-coloured status LED Non-frangible element fitted as standard (conforms to EN54) Addressed with TCH-B100 Hand Held Programmer Surface or flush mounting (if surface mounting, requires SR MOUNTING BOX, sold separately) Different colour options available LPCB Approved to EN54 -
Fast response Status LED Non-frangible element fitted as standard (conforms to EN54) Addressed with TCH-B100 Hand Held Programmer Surface or flush mounting (if surface mounting, requires SR MOUNTING BOX, sold separately) LPCB Approved to EN54 -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes White LEDs Colour-matched with existing sensor range -
High Intensity LED technology Addressable via Hand Held Programmer (TCH-B100) Up to 127 devices per loop Approved by VdS -
Approved to MED by GL SIL Level 2 approved variant available Ideal for use in oil and gas environments Fast response Integral short-circuit isolator Bi-coloured status LED Non-frangible element fitted as standard (conforms to EN54) Addressed with TCH-B200 Hand Held Programmer Surface or flush mounting (if surface mounting, requires SR MOUNTING BOX – sold separately) LPCB Approved to EN54 -
Low profile - only 2” high Simple and reliable device addressing Supports 16 operational modes Automatic compensation for sensor contamination Built-in fire test feature Uses the noise-immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires Two built-in power/alarm LEDs Programmable non-polling LEDs Non-directional smoke chamber Vandal resistant security locking feature 10 years CO sensor life span* -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes Red LEDs Colour-matched with existing sensor range -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes White LEDs Colour-matched with existing sensor range -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes Red LEDs Colour-matched with existing sensor range -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes White LEDs Colour-matched with existing sensor range -
Key Features:; EN54-23 compliant Loop powered High intensity flash Range of coverage volumes Red LEDs Colour-matched with existing sensor range -
Compatible with the majority of existing Analogue and Conventional bases Colour matches standard Hochiki Analogue and Conventional sensor/detector/base ranges 4 pre-moulded knock-outs provide wiring entry Low profile - only 16mm -
Loop Powered with Single Loop Address - addressed automatically by Control Panel or via the TCH-B200 Hand Held Programmer Variable Sound Output 50 ~ 98 dB(A) (+/-2 dB(A)) output at 1 metre 51 User-Selectable Tones (all tones EN54-3 compatible) Auto-Shutdown feature prevents noise-pollution -
EN54-23 compliant O Rated Single Loop Address - addressed via the TCH-B100 Hand Held Programmer Variable Sound Output 50 ~ 98 dB(A) (2 dB(A)) output at 1 metre Sounder and Beacon can operate independently 0.5 or 1Hz flash frequency Fits Hochiki Standard or Isolator Base and supports ESP Sensors, Addressable Beacons and Addressable Remote Indicator 51 User-Selectable Tones (all tones EN54-3 compatible) Auto-Shutdown feature prevents noise-pollution Also available in white or black