/Kentec Electronics
  • 2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points
    Details
  • Key Features:; High brightness red LED indicators for reliability and low power consumption Wide viewing angle LEDs flash alternately to easily attract attention Units to fit to standard gang or round electrical back boxes Compatible with conventional and addressable detectors Printed with “FIRE ALARM IN CON CEALED SPACE” as standard Custom printing and languages available on request
    Details
  • 2.5A and 5.25A versions Chassis only or enclosure mounted with battery space 110V or 230V input Regulated, true 24V output Intelligent battery charging and temperature compensation House up to 26Ah batteries Status indicators for monitored faults Dual output option for powering fire alarm control panels remotely Chassis versions have same mounting points
    Details
  • Fully welded, all steel construction Tough epoxy powder coated finish Key lockable Wide range of styles and sizes Up to 65Ah batteries can be fitted Fully enclosed and robust construction
    Details
  • Key Features:; Available with red or yellow high brightness, flashing LED indicators Can be used for Fire alarm warning, activated by a sounder circuit or to indicate and initiate an active isolation Optional silence buzzer keyswitch Disable buzzer option via internal jumper link Optional Keyswitch to perform isolation Terminations for incoming and outgoing wiring Surface mounted box supplied Front panel can be fitted to a single gang UK back box
    Details
  • Key Features:; Available with red or yellow high brightness, flashing LED indicators Can be used for Fire alarm warning, activated by a sounder circuit or to indicate and initiate an active isolation Optional silence buzzer keyswitch Disable buzzer option via internal jumper link Optional Keyswitch to perform isolation Terminations for incoming and outgoing wiring Surface mounted box supplied Front panel can be fitted to a single gang UK back box
    Details
  • Key Features:; 2 minutes to fit on site Kit available from stock Colour to match standard Control Panel ranges Special colours available on request Attractive design Key lockable
    Details
  • "Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface"
    Details
  • "Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs"
    Details
  • "Two-wire and standard versions in two, four or eight zones Compatible for use on BS5839: Part 1: 2017 installations Two-wire repeaters and ancillary boards Simple, single board construction Compatible with wide range of detection devices Two monitored sounder outputs Three Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
    Details
  • "Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
    Details