  • Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms, and self-test (active repeater only) “Access Enable” key-switch on active repeater
    Details
  • Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms, and self-test (active repeater only) “Access Enable” key-switch on active repeater
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
    Details
  • Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
    Details
  • Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
    Details
  • Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
    Details
  • Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
    Details
  • Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
    Details
  • Characteristics common to the rest of the S2 range described in the MI-PSE-S2 detector. Dimensions in mm: 102 Ø x 43 (height) mounted on base B501AP Approved according to: EN54-7 CPD Certificate: 0832-CPD-0195
    Details
  • Key Features:; Unique ‘Plug & Play’ installation concept Re-settable operating element option Analogue addressable communications Fully compliant with EN54, Part 11 Backward compatibility Enhanced aesthetics Integral LED Integral loop isolation option
    Details
  • EN 54-3 compliant Suitable for 12 V and 24 V DC service voltage Synchronous sound trigger Volume adjustable to 2 levels at the device
    Details
  • EN 54-3 and 54-23 compliant Synchronous sound and flash trigger Volume adjustable to 2 levels at the device C & W category Signal range up to 6.0 m room width for wall mounting Signal range up to 8.9 m room diameter for ceiling mounting
    Details
  • Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder Low current draw enables more devices on loop Adjustable volume control (on device or from panel) Intense strobe output Deep and high IP base options Pure White or Ivory body colours Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel)
    Details
  • Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls
    Details
  • Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls
    Details
  • Key Features:; Large cable access EN54-3 Approved Rear or surface cable entry Loop continuity spring Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls
    Details
  • Key Features:; Large cable access Rear or surface cable entry Loop continuity spring Automatic synchronisation of sounder and strobe Common base with detectors (B501AP) Morley IAS Protocol 32 tone selection to cover many markets (on device or from panel) Positive “poke yoke” engagement Address tag for clear indication Anti-tamper feature In-built isolation options Simple familiar rotary wheel address controls
    Details