/Notifier
  • 240 x 60 Graphic LCD H165mm x W254mm x D50mm Requires external power source
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Extended capacity:; The Pearl supports up to 636 loop devices (159 detectors plus 159 modules per loop) Longer loops, but fewer of them, will give the opportunity to save on installation time, cost and wiring Highly resilient Opal system, able to pinpoint a loop fault whilst maintaining full system operation Powerful networking capability - Up to 16 Pearl panels, controlling over 10,000 devices, can be networked via the superfast ID2net; prioritising a fire signal to communicate across a network in under three seconds; Intuitive on-site management - backlit buttons for fast, error free situation management, and large display giving complete information at a glance Simpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector status Text programming via MS Excel spread sheet User permissions set per individual password; Unique first fix bracket with adaptations for 19” rack or flush mounting. Fast system set up and commissioning via the panel, loop “Autolearn” and advanced PC tools suite Comprehensive “Cause & Effect” programming capability Panel sounder and beacon synchronisation System extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cabling Separate text change without risk to “Cause & Effect” or system configuration. Ability to run BS5839 part 6 system for HMO
    Details
  • Quickly identify the location of a fire related incident Designed to comply with EN54 Part 2 Simple connection to ID panels Active & Passive options Power diagnostics Push button test Language options Windows‚ based off-line configuration tool
    Details
  • Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Key Features:; Compatible with the Notifier Range of Analogue Addressable Fire Alarm Control Panels. Including the Notifier ID3000, Notifier ID2000, Notifier ID50 and Notifier ID60 Panels. Part of the New Notifier Opal Range of Analogue Addressable Detectors. Colour : Ivory (To Match Colour of Previous Notifier Detectors and Bases) New Replacement for the Notifier SDX-751EM Detector Backwards Compatible with Existing Notifier Systems LPCB Approved Tri Colour LEDs
    Details
  • How the SMART4 works; Unique, true four sensor Multi-criteria detector Fully integrated Infra-Red sensor to support the fire alarm decision CO gas sensing for fastest response to slow developing and smouldering fires Highest possible immunity to unwanted alarms Automatic drift compensation of smoke sensor and CO cell Twin LED indicators providing 360° visibility Wide temperature range Built in test switch Stable communication with high noise immunity
    Details
  • Extremely high sensitivity, high power output IR LED and high gain IR receiver amplifier based smoke sensor Improved signal stability using the latest LED technology for professional applications Redesigned smoke chamber to further reduce the risk of false alarms 3-colour LED’s to locate alarms and speed up diagnostics and fault finding Integrated and controlled isolators Support for the latest OPAL protocol which offers superior performance and diagnostics capabilities Full backward compatibility with existing systems Rotary decade address switches
    Details
  • Advanced laser light source and patented optical design. Notifier Analogue Addressable communications protocol provides extremely reliable operation proven in millions of worldwide detector installations. Sensitivity: 9 levels from 0.07% to 6.56% obs/m. Rotary DECADE address switches. Dual bi-colour (red/green) LEDs flash green when Normal and are steady red in Alarm. Dual LED design provides 360° viewing angle. Built-in magnetic test switch, or automatic test commanded from panel.
    Details
  • Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details