/Notifier
  • Key Features:; Proven reliability with a feature set that offers significant benefits to the customer Certified to EN54 Part 11 Single Pole Key removable in both positions
    Details
  • Automatic drift compenstation Programmable Sensitivity Advanced maintenance features via remote hand-held test unit Low profile design Low current draw Wide operating voltage 8 to 30VDC Bi-colour LED detector status indicator Addressable alarm location feature Approved to EN54 part 7 (2000) 3 Year warranty
    Details
  • Automatic drift compensation Programmable Sensitivity Advanced maintenance features via remote hand-held test unit Low profile design Low current draw Wide operating voltage 8 to 30VDC Bi-colour LED detector status indicator Addressable alarm location feature Approved to EN54 part 7 (2000) 3 Year warranty
    Details
  • Automatic drift compensation Programmable Sensitivity Advanced maintenance features via remote hand-held test unit Low profile design Low current draw Wide operating voltage 8 to 30VDC Bi-colour LED detector status indicator Addressable alarm location feature Approved to EN54 part 7 (2000) 3 Year warranty
    Details
  • CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
    Details
  • Faster installation - The large cable access, rear or surface cable entry options and innovative loop continuity spring all make for faster more cost effective installation. Reduced install errors and easy fault finding - devices are mounted using a positive push and turn engagement system and are supplied with an address tag for clear identification. Isolation is built-in to each device and addressing is made simple by familiar rotary wheel address controls. In addition each device incorporates an anti-tamper feature giving added security. Excellent system performance - High light output and a selection of 32 sounder tones can be synchronised via the Notifier control panel to provide fast clear warning of a fire related incident. Flexible installation - The low current draw of the devices enables more devices on each loop. This combined with the wide range of devices and mounting options including deep and high IP options, white or red colour options and sounder volume controllable from the panel or the sounder itself all make for greater flexibility for the system designer. Reduced lifetime costs - each device in the Opal AV range is constructed from high quality UV stable materials, designed for impact resistance and years of trouble free operation. If changes to a system are required the universal system base means a sounder/beacon can be added without re-wiring. Reduced inventory count - Notifier’s Opal AV range now utilizes the B501AP system base,- common to detectors. The Opal AV range is designed to maximise the features of Notifier’s advanced digital Opal protocol but remains backward compatible with previous Notifier communication protocols so can be used for retrofit and replacement for older systems. Opal AV devices provide both standard wall mounting units and integrated base units allowing the direct fitting of Notifier detectors. Wall mounting units are available as a sounder, sounder & beacon combination and a beacon only with sounder colour options of both red and white. Integrated base sounder units are also available as either a sounder or a sounder and beacon combination in colours to match the detectors.
    Details