-
Low Power – The power consumption of the repeater has been minimised through energy efficient design, preserving loop current and capacity. Quiescent 1.6mA, Alarm 12.7mA Installation – The repeater can be surface or flush mounted as standard, allowing gland or conduit entrance through the rear, top or bottom of the enclosure. The device only requires a loop connection to provide both power and data, no network cabling, or external power supply is required. Event Display – Events are categorised and clearly displayed for intuitive navigation of the system status, whilst large graphical indicators show a general system overview. User Assistance – A help menu displays a list of status specific tool-tips to aid the user in accomplishing tasks, such as silencing the internal buzzer or performing a lamp test. If the user requires additional help, the contact details for site engineers and the installer are available on the screen. Multi-Language Support – The 6000/LOOP/REPEATER’s graphical user interface caters for most Western European languages and Arabic script as standard. The language for event strings is inherited from the control panel. USB Configuration – The fast USB configuration tool allows the device to be programmed with site specific data, such as contact details for site engineers and the installer along with custom logos and settings. -
Key Features:; Cost Effective Single Loop Panel High Capacity Loop – 192 Addresses Algo-Tec 6000Plus Protocol Surface and Recessed Mounting Easy to Install Reduced False Alarms Enhanced Performance On Site Flexibility Designed to EN54-2 & 4 -
High specification interactive digital addressable fire detection and alarm system, providing a cost effective solution for small, medium and large sized builds and sites Up to 32 control panels, repeats and illuminated zonal mimics can be networked enabling system design and expansion to be easily achieved to suit the site for economic wiring and operational convenience Wires as a loop, the network’s dual channel RS485 link ensures no single fault will affect the system An extensive range comprising loop powered alarm sounders, beacons, interfaces, manual call points and sensors can all be connected to the nearest control panel using a single 2-core cable for each of the high capacity loops (up to 4), accommodating up to 191 devices per Loop, 512 maximum per panel. -
Key Features:; Distributed network of display and control nodes (DCN’s) and loop processing nodes (LPN’s) providing a cost effective solution for medium and large sized buildings and sites Wires as a loop, the network’s dual channel RS485 link ensures that no single fault will affect the system Alarm sounders, beacons, interfaces, manual call points and sensors can all be loop powered The Protec Algo-Tec 6000 interactive fire sensor utilize advanced discrimination algorithms for maximum reliability and immunity to false alarms. -
Clear backlit alphanumeric / LED displays Compact size Loop powered, no separate supply required -
Secure Network; : -
Protec Algo-Tec 6000PLUS Protocol Ideal for detecting shouldering fires Devices display address numbers Easy to address FAST addressing Reduce false alarms -
Dual Technology Sensor Combined Smoke and Heat Sensors Ideal Multi-application Sensor Independent Channel Control Day/Night Operation Protec Algo-Tec™ 6000 Protocol Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms -
Key Features:; Protec Algo-Tec™ 6000 Protocol Ideal where Smoke Detection is Unsuitable Fast Response Thermistor Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms -
Key Features:; Ideal where Smoke Detection is Unsuitable Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing -
Ideal Where Smoke Detection is Unsuitable Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Electronic Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing Reducing False Alarm VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Sensor VAD; -; Dual Technology Sensor Combined Smoke and Heat Sensor Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Integral Short Circuit Isolator Devices Display Address Number VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume -
Key Features:; Ideal where smoke detection is unsuitable Fast response thermistor Integrated electronic sounder Loop powered Low current Programmable volume control Integral short circuit isolator Sounder tone selectable at control panel Devices display address number -
Fast response thermistor Integrated electronic sounder Integrated high intensity LED beacon Loop powered Low current Programmable volume control Integral short circuit isolator Devices display address number -
Ideal where smoke detection is unsuitable Fast response thermistor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered Low current Programmable volume control Integral short circuit isolator Devices display address number -
Key Features:; Dual technology sensor Combined smoke and heat sensors Ideal for multi-purposes Independent channel controls Day / night operation Protec Algo-Tec 6000PLUS Protocol Devices display address number Fast addressing Reduce false alarms -
Dual technology sensor Combines smoke and heat sensor Ideal multi-application sensor Integrated high intensity LED beacon Low powered Low current Integral short circuit isolator Devices display address number FAST addressing and reduces false alarms -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number FAST addressing and reduced false alarms -
Dual technology sensor Combines smoke and heat sensor Ideal multi-application sensor Integrated electronic sensor Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number -
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator -
Key Features:; Multiple technology sensors Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Day / night operation Protec Algo-Tec 6000PLUS protocol Devices display address number FAST addressing Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated high intensity LED beacon Loop powered / low current Integral short circuit isolator Devices display address number FAST addressing Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Protec Algo-Tec 6000PLUS Protocol Unprecedented false alarm rejection -
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Unprecedented false rejection -
Multiple technology sensor Combined smoke, heat and CO sensors Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator -
Key Features:; Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Key Features:; Unique Installation Concept Anti-Tamper Facility Enhanced Aesthetics Fully Approved to the Latest Standards Re-settable Break Glass Element Backward Compatibility -
Protec Algo-Tec 6000 Protocol Loop powered High intensity LEDs Extremely long service life Integral short circuit isolator Ultra low current consumption Weather-proof to IP65 -
Protec Algo-Tec 6000 Protocol Loop powered High output electronic sounder High intensity LED beacon Low current consumption Choice of colours Weatherproof to IP65 Integral short circuit isolator -
LED Technology for Long Service Life Quick and Simple to Install FAST™ Addressing Loop Powered and Integral Short Circuit Isolator High Output Electronic Sounder 2.4 Metres (m) Mounting Height Adjustable 7m to 5m or 3m Room Coverage Volume Approved to EN54 Part 3, 17 & 23