/The Fire Beam Company
  • Very Low Power: using only 3.5mA any state opens up a whole world of options. In some cases you can loop power the beam, for instance using an Apollo xp95 mini switch monitor allows you do just that and turns the conventional Fire Beam into an addressable unit. IP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can't set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams all the moving optics are safely encased inside the waterproof enclosure so you won't accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment. Hysteresis: Changing the hysteresis will change the delay in returning from a fire state back to a normal state. For example, the beam is factory set at 15% so if the beam falls into fire at 65% (35% threshold) it has to recover 15% to 80% before it returns to normal. This action prevents small fluctuations in returned signal causing the beam to fall in and out of a fire state. This can be adjusted to anywhere between 1% and 40%. The hysteresis can simply be adjusted from this new menu option. Beam Phasing: It is possible that beams that face each other will cause problems as their sample rates could coincide and result in unreliable readings, meaning false auto-alignment and unreliably in service. With the introduction of phasing it is now possible to mount beams facing each other with reflectors in-between. There are up to 7 different sampling rates to choose from, alleviating any cross talk problems. Auto-Align Time Delay: Again this facility is useful in environments that are liable to occasional short term obscuration. Pre-set at 4 hours this can be altered to anywhere between 0 to 12 hours if required, to allow the environment to clear. Multi Language Support: The Fire Beam Plus has the ability to display seven different languages: English, German, Spanish, French, Italian, Dutch, and Czech.
    Details
  • Very Low Power: using only 3.5mA any state opens up a whole world of options. In some cases you can loop power the beam, for instance using an Apollo xp95 mini switch monitor allows you do just that and turns the conventional Fire Beam into an addressable unit. IP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can't set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams all the moving optics are safely encased inside the waterproof enclosure so you won't accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment. Hysteresis: Changing the hysteresis will change the delay in returning from a fire state back to a normal state. For example, the beam is factory set at 15% so if the beam falls into fire at 65% (35% threshold) it has to recover 15% to 80% before it returns to normal. This action prevents small fluctuations in returned signal causing the beam to fall in and out of a fire state. This can be adjusted to anywhere between 1% and 40%. The hysteresis can simply be adjusted from this new menu option. Beam Phasing: It is possible that beams that face each other will cause problems as their sample rates could coincide and result in unreliable readings, meaning false auto-alignment and unreliably in service. With the introduction of phasing it is now possible to mount beams facing each other with reflectors in-between. There are up to 7 different sampling rates to choose from, alleviating any cross talk problems. Auto-Align Time Delay: Again this facility is useful in environments that are liable to occasional short term obscuration. Pre-set at 4 hours this can be altered to anywhere between 0 to 12 hours if required, to allow the environment to clear. Multi Language Support: The Fire Beam Plus has the ability to display seven different languages: English, German, Spanish, French, Italian, Dutch, and Czech.
    Details
  • New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place. Five Times Faster: We have designed completely new linear stepper motors which have resulted in amazingly fast commissioning and routine maintenance. Under test conditions at 40 metres we recorded an auto-align time of 3m02s using the Fire Beam straight out of the box. Once aligned a routine re-alignment was timed at just 1m07s. This is class-leading performance not only in terms of speed but also in terms of advanced robust design built for precise purpose. Multi Language Support: The Fire Beam Xtra has the ability to display seven different languages: English, German, Spanish, French, Italian, Dutch, and Czech. A feature that is welcomed by our ever increasing international customers as we now sell to 62 countries around the world. Auto-Align On/Off: Although rarely needed, this facility allows you to turn off the auto-alignment in normal service, should the environment be liable to occasional contamination (such as theatres with fake smoke). As motorised beams work by seeing the reflector, if they are unable to because of unavoidable obscuration they can fall out of alignment when trying to find the obscured reflector. The Fire Beam Xtra will remain in perfect alignment in these environments simply by not trying to re-align itself. Auto-alignment will still continue to work in commissioning modes. This facility is best suited to beams that are mounted on solid surfaces that are not susceptible to building movement at all. For buildings that are liable to movement (such as metal warehouses) we have also built in a new delay function that can be used instead (see below). Auto-Align Time Delay: Again this facility is useful in environments that are liable to occasional short term obscuration. Adding a delay means that the beam will not check for alignment if the received signal drops for a predetermined time. Pre-set at 4 hours this can be altered to anywhere between 0 to 12 hours if required, to allow the environment to clear. Beam Phasing: It is possible that beams that face each other will cause problems as their sample rates could coincide and result in unreliable readings, meaning false auto-alignment and unreliably in service. With the introduction of phasing it is now possible to mount beams facing each other with reflectors in between. There are up to 7 different sampling rates to choose from, alleviating any cross talk problems. Hysteresis: Changing the hysteresis will change the delay in returning from a fire state back to a normal state. For example, the beam is factory set at 15% so if the beam falls into fire at 65% (35% threshold) it has to recover 15% to 80% before it returns to normal. This action prevents small fluctuations in returned signal causing the beam to fall in and out of a fire state. This can be adjusted to anywhere between 1% and 40%. The hysteresis can simply be adjusted from this new menu option. Up to 160 Metre Range: With new enhanced optics you can cover distances up to 160 metres, meaning for distances over 100 metres you no longer need to use two beams, saving both time and money. Very Low Power: using only 3.5mA any state opens up a whole world of options. In some cases you can loop power the beam, for instance using an Apollo xp95 mini switch monitor allows you do just that and turns the conventional Fire Beam into an addressable unit. IP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can't set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams all the moving optics are safely encased inside the waterproof enclosure so you won't accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment.
    Details
  • New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place.
    Details