-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; Flame Detector - Data Sheet
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; Flame Detector - Data Sheet
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; Flame Detector - Data Sheet
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; S200 Flame Detector - Data Sheet
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire; Flame Detector - Data Sheet
-
Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
-
Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
-
Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
-
Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
-
Key Features:; Solar Blind for false alarm free operation Fast response to flames Detect a 0.1m² fire at a range of 20m Automatic health check feature Discrete ultra-low profile design Fits a standard MZX detector base or functional base Integral alarm LED with 360º angle of view Use T110 infrared test source (With separate adapter); 601F-M Detector - Data Sheet
-
Tyco MD611EX - Data Sheet
-
Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; High Performance Optical Smoke Detector - Data Sheet
-
Features:; Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors; Infa-Red Flame Detector - Data Sheet
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; Rate Of Rise Heat Detector - Data Sheet
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; CO & Rate Of Rise Heat Detector - Data Sheet
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Intrinsically Safe Weatherproof to IP67 Compatible with System 620; Conventional Call Point - Data Sheet
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Polyester Enclosure - light, strong and not subject to corrosion. Break Glass. Explosion protected EExe (ATEX Approved). In line and end of line resistors. Red. 9 x terminals. Lift flap for extra protection against inadvertent operation. 1 x changeover switch. Captive cover screws. No hammer required - the glass is covered by a membrane thus protecting the operator from glass fragments. Key operated test facility - simple but secure. 2 x M20 bottom cable entries.
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Intrinsically safe Weatherproof to IP66/IP67 Robust GRP Housing; Model: BG3I 514.001.059 Intrinsically Safe Callpoint (BG3I4NBN) Protection: Explosion Protected EExia (Intrinsically Safe) Certification: CENELEC EN50014, 020 BASEEFA EExia IIC T4 Cert No. BAS00ATEX1067X Suitable for use in Zones 0,1 & 2 Voltage: Up to 28V (IS) Certified Temp: -55°C to +55°C Ingress Protection: IP66 & IP67 European Standard for Callpoints: EN54-11 Terminals: 6 X 4.0mm2 Cable Entries: 2 X M20 Bottom Weight: 0.5Kg Material: UV resistant glass reinforced polyester Finish: Natural Red GRP
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) Suitable for use in Zone 0,1 & 2 Robust GRP Body Suitable for offshore and petrochem Certificated Intrinsically Safe; Certification: CENELEC EN50014, 20 & 39 BAS02ATEX1258X EExia IIB T4 Zones 0,1 & 2 Material: UV stable glass reinforced polyester body. Clear polycarbonate cover/lens. Retained stainless steel cover screws. Finish: Painted Red Tube Type: Xenon discharge Lens Colour: Clear Terminals: 8 x 2.5mm2 Flash Rate: 1 flash per second Cable Entries: Up to 3 x M20 via knockouts Tube Energy: 0.5 Joules Weight: 1.4kg Certified Temperature: -55°C to + 60°C Ingress Protection: IP66 & IP67 Tube Life: >1 x 106 Flashes Voltage: 24V via suitable barrier Current Consumption: 71mA max nominal
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 For use in hazardous areas Robust GRP construction Powerful Output, up to 118dBA; Terminals: 6 x 2.5mm2 Mounting: Stainless steel bracket with ratchet facility Cable Entries: 2 x 20mm EExd. Tone Selection: 27 user selectable tones. Certification: CENELEC EN50014,18,19 BASEEFA Cert. No. BAS00ATEX2097X, EExd IIC. Zones 1 and 2. Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Swivel bracket & captive cover screws in stainless steel. Nominal Output (dBA) Input Current (mA)* 93 50 105 100 108 150 111 200 112 250 114 300 115 350 118 380 Product Code 576.501.049 Flameproof Horn Sounder (DB3D048N2BNR) Output measured with 24VDC input voltage. Tone set to 970Hz continuous. Weight: 6.0kg approx Ingress Protection: IP66 / IP67 Voltage: 12VDC to 48VDC Certified Temperature: -20o C to +70o C
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Robust Corrosion Resistant GRP body High Power (5 Joule) Certificated Flameproof; Voltage: 24Vdc Tube Energy: 5 Joules Peak Current Consumption (mA): 320 Effective Intensity (Cd): 29 Peak Intensity (Cd): 22213 Power Consumption (Watts): 8 Note: The Cd figures are for a clear lens @ 1Hz flash rate. For red lens multiple by 0.15 Weight: 2.5Kg Certified Temperature: EExd -55°C to + 70°C (T4) -55°C to + 55°C (T5) -55°C to + 40°C (T6) Ingress Protection: IP66 & IP67 Terminals: 6 x 2.5mm2 Entries: 2 x 20mm ISO EExd. Certification: BASEEFA EExd IIB 135°C (-55 to AMB +70°C)T4 100°C (-55 to AMB + 55°C)T5 85°C (-55 to AMB + 40°C)T6 Cert. No. 99 ATEX 2195X. CENELEC EN50014 and EN50018 Material Body: Glass reinforced polyester Lens: Glass Cover Screws + Backstrap: Stainless steel 316 Finish: Red
-
MUBEX Base Installation & Commissioning Instructions
-
Key Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire