-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
-
Unrivalled black body rejection over a wide range of source temperatures Triple waveband infrared solar blind flame detection for optimum false alarm immunity Discrimination of optical faults (dirty windows) from other faults in the built-in self-test Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
-
-
-
-
Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces Reduces cabling, no interface required No additional power source required Easy installation uses a common plug in base for smoke and heat detectors Can be used on all vessels as fully marine approved
-
-
Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S)
-
Continuous detection despite extremely large monitoring area Easy and rapid installation of the maintenance-free sensor cable Very high resistance to extremely contrary ambient influences(immune against heat, cold, humidity, corrosion, strong winds and draft) Undiminished precision under electromagnetic interference Unprecedented security against false alarms Very high sensor cable service life of up to 30 years Temperature profile over the complete measurement range delivers exact information of location, size and spreading of the fire Very low maintenance costs as the maintenance and the trouble shouting can be done from the control unit VdS certified to EN 54/5-A1 One controller unit will drive up two 8km spurs or one 8km loop Easy integration into existing installations Each sensor cable divided into up to 256 zones Individual configuration of 5 alarm criteria per zone Good network connection through Modbus, TCP/IP, FTP and SCPI interfaces
-
ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices